Understanding the system status using the LEDs topic in the troubleshooting
section of the Storwize V3700 Information Center.
3. Wait for all expansion canisters to finish powering on.
4. Plug the power cord of each power supply in the control enclosure into a
properly grounded electrical outlet.
Note: Each enclosure has two power supply units. To provide power failure
redundancy, connect the two power cords to separate power circuits.
5. Check the LEDs on each node canister in the control enclosure (see Figure 37).
1
Figure 37. Node canister LEDs
1 Power
v
2 Status
v
3 Fault
v
The canister is ready with no critical errors when Power is illuminated, Status
is blinking, and Fault is off. If a canister is not ready, refer to the Procedure:
Understanding the system status using the LEDs topic in the troubleshooting
section of the Storwize V3700 Information Center.