Handling Precautions; Terminology - Panasonic IO-Link SC-LG-CEF User Manual

Configuration tool
Table of Contents

Advertisement

1.1 Handling Precautions

1.1 Handling Precautions

■The following symbols are used to indicate safety information that must be observed.
Information
Reference
Caution

1.2 Terminology

Master station
Slave station
SC-LG2-CEF-P
CC-Link IE Field net-
work
Cyclic transmission
Transient transmission
CC-Link IE
Field related
Memory map
Link device
Network number
Station number
Intelligent device sta-
tion
1-2
Indicates an action that is prohibited.
Indicates an action that must be taken.
Indicates a matter that requires caution.
Indicates supplemental information.
Indicates reference to details about the subject in question.
Indicates points to be noted when the product is operated.
Term
A station that controls the entire network. This station can perform cyclic
transmission and transient transmission to all stations.
A generic name of all stations other than master stations (local stations,
remote I/O stations, remote device stations, and intelligent device sta-
tions)
An IO-Link master compliant with CC-Link IE Field.
This master connects IO-Link devices using e-CON connectors.
PNP connection is based on the I/O interface specifications of IO-Link
devices.
A high-speed and large-capacity open field network using Ethernet
(1000BASE-T)
A function that periodically exchanges data between stations on the
same network in the data link layer
A function that uses the read/write instructions of the program at the lo-
cal station to read and write data from / to remote stations and commu-
nicate with remote stations via peripheral devices in the data link layer
A memory map where the functions of the communication unit are al-
located to link devices. The master station can use the functions of
the communication unit by accessing the link devices allocated on the
memory map.
Internal devices held by the unit (RX, RY, RWr, and RWw)
A unique number that is assigned to identify each network when mul-
tiple networks are created.
Duplicate numbers cannot be set among all networks.
A unique number that is assigned to identify each network unit that is
connected to a network.
Duplicate numbers cannot be set among all network units within a net-
work.
A station that cyclically transmits bit-based I/O signals and word-based
I/O data to the master station. This station returns responses to tran-
sient transmission requests from other stations.
Description