3.8 Device Diagnosis Window

This window displays diagnosis information for the IO-Link device selected in the tree on the left
side of the window.
If you select an IO-Link device in the tree, a device diagnosis subwindow will be displayed in the
Diagnosis tab.
Name
1
Status
2
Status details
3
Operating Time
4
Stored Count
Information
The Diagnosis tab is displayed only when a Panasonic IO-Link device is selected.
WUME-SCLGCT-3
4
The status of the current IO-Link device is displayed.
The status is Normal, Notification, Caution or Abnormal.
Details are displayed when the status is Notification, Caution, or Abnormal.
Notification:
Measurement error, reduced amount of entering light, unstable entering
light, or applied voltage during zero-point adjustment
Caution:
Operating time limit exceeded or nonvolatile memory saving count limit
exceeded
Abnormal:
DC output short-circuit, nonvolatile memory error, or damaged LED cir-
cuit
The amount of IO-Link device operating time is displayed.
The number of write operations to the IO-Link device is displayed.