Q-1 Glass Adjustment
Proper adjustment of the side-to-side position on the
glass clamp on Vieler Streamline hardware such as used
on Hussmann Q series service cases is critical to proper
operation of the glass hardware. Failure to properly adjust
the glass clamp can result in failure of the hardware and
possible injury to personnel.
When setting or repairing cases, the glass clamp is
frequently adjusted from side to side once the cases are
set in order to control glass gaps or compensate for poorly
installed case line ups. Due to the unique design of this
type of hardware, using practices common to other types
of hardware can result in the above failures.
Step 1: Level Case
The canopy hardware and glass gaps are set at the factory
for proper fit with the Cases Square and level. Before
attempting to do any adjustment of the canopy hardware,
ensure that the cases are set square and level. Additionally,
the adjoining cases must be pulled together tightly.
Installation (Cont'd)
To adjust the front glass please follow these steps
Before you start any adjustments make sure the cases are
level, Front to Back and side to side
Step # 2
To level the cases remove the front and rear close-offs, You
can adjust the Height by turning the base leg adjusters
When you turn the leg adjuster clock-wise the case will
go up.
When you turn the leg adjuster counter clock-wise the
case will go down.