TY3ECRC and TYA3ECRC
(ENTYCE)
END/ISLAND CASE
EXTENDED CANOPY
ROUND CORNER
SELF-CONTAINED
I N S TA L L AT I O N & O P E R AT I O N G U I D E

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann TY3ECRC

  • Page 1 TY3ECRC and TYA3ECRC (ENTYCE) END/ISLAND CASE EXTENDED CANOPY ROUND CORNER SELF-CONTAINED I N S TA L L AT I O N & O P E R AT I O N G U I D E...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS General Information --------------------------------------------------- 4 Installation Checklist --------------------------------------------------- 5-6 Section and Plan Views --------------------------------------------------- 7 Data / Spec Sheets --------------------------------------------------- 8-10 Installation --------------------------------------------------- 11 Evap Pan Information --------------------------------------------------- 11 Clearances for Case --------------------------------------------------- 12 Body Panel Removal --------------------------------------------------- 13 Lifting Instructions --------------------------------------------------- 14-15 Electrical Information...
  • Page 3 1. Do Not Push, Pull, Adjust, or Manipulate the Entyce case by any glass component • Doing so will result in severe damage to such components • Glass or Acrylic Breakage may result in serious injury • See lifting and transport instructions for proper moving technique ref.
  • Page 4: General Information

    Shortages: Check your shipment for any possible shortages of material. If a shortage should exist and is found to be the responsibility of Hussmann Chino, notify Hussmann Chino. If such a shortage involves the carrier, notify the carrier immediately, and request an inspection. Hussmann Chino will acknowledge shortages within ten days from receipt of equipment.
  • Page 5: Installation Checklist

    Cases Check / Initial Prior to beginning review the installation manual on moving, lifting, and setting the case Report any damage to Hussmann Account Manager or Sales representative right away Shipping pins, boards, clips, tape removed and disposed of Intake must be facing away from store entrance doors Height clearance measured from the floor must be minimum 10 ft vertically Minimum of 36 in.
  • Page 6 Inspect honeycomb for dust buildup. Remove and clean with warm water and mild soap. This checklist is a supplement to the provided installation manual and should be completed to ensure that all installation procedures were completed and verify normal case operation at startup. Hussmann Tech Support 866-785-8499...
  • Page 7: Section And Plan Views

    Cut and Plan Views...
  • Page 8: Data / Spec Sheets

    Spec Sheets SELF-SERVICE DELI REVISION DATE 04/07/21 HUSSMANN – TY(A)3ECRC-5X7I-S SELF-CONTAINED REFRIGERATION DATA: CONVENTIONAL AVERAGE DISCHARGE VELOCITY CAPACITY *** AIR** (°F) (SEE CASE LENGTHS CASE USAGE (FT/MIN) (BTU/HR) SETPOINTS BELOW) 5X7I DELI TYPE 1 15470 30 ~ 34 125~175 5X7I...
  • Page 9 SELF-SERVICE DELI REVISION DATE 04/07/21 HUSSMANN – TY(A)3ECRC-3-S SELF CONTAINED REFRIGERATION DATA: CONVENTIONAL AVERAGE DISCHARGE VELOCITY CAPACITY *** AIR** (°F) (SEE CASE LENGTHS CASE USAGE (FT/MIN) (BTU/HR/FT) SETPOINTS BELOW) 4.5E, 5.5E DELI 2100 28~32 125~175 **FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB...
  • Page 10 SELF-SERVICE DELI REVISION DATE 04/07/2021 HUSSMANN – TY(A)3ECRC-4X6E-S REFRIGERATION DATA: AVERAGE CONVENTIONAL DISCHARGE AIR* VELOCITY (°F) CASE LENGTHS CAPACITY ** CASE USAGE (FT/MIN) (SEE SETPOINTS (BTU/HR/FT) BELOW) SS DELI 2100 32~36 125~175 *FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB **REFRIGERATION NOTES: 1) CAPACITY FOR REFERENCE ONLY.
  • Page 11: Installation

    Installation Store Conditions Do Not Install the Vented Panels of the self-contained model against a wall or • Case is designed to operate at temperatures at either 75°F at 55% relative humidity or 80°F at 55% relative hu- other storage fixture midity.
  • Page 12: Clearances For Case

    Figure1 EVAPORATOR PAN Clearances Minimum Clearances for Self-Contained cases are to be followed as instructed for proper placement inside store locations. - Intake and exhaust clearances are to be a minimum of 8 ft when placed next to a solid wall. - Height clearance measured from floor follows as a minimum of 10 ft vertically.
  • Page 13: Body Panel Removal

    Body Panel Removal The merchandiser’s body panels are designed with slots located on top and bottom. The body panels are held in place by retaining clips located at the top of the case which the slots slide into and resting hooks located at the bottom of the case which the slots rest onto.
  • Page 14: Lifting Instructions

    (CENTERED) Dollies under each Base Leg 1. The TY3ECRC is not recommended to be lifted by a forklift due to critical refrigeration components underneath mer- chandiser. For the safest process defer to using J-Bars WARNING Use of forklift may damage critical refrigeration components and or drainage piping.
  • Page 15 Lifting Instructions (Cont’d) 8. While using J-Bars, use the specified set points to support the case based of the size of dollies being utilized. • Raise one end of the case first. • One J-Bar is usually sufficient to lift the case, use multiple J-Bars at specified lift zones if one does not satisfy the safe lift of the merchandiser.
  • Page 16: Electrical Information

    Electrical Field Wiring and Serial Plate Amperage Standard Case Wire Color Code Field Wiring must be sized for component amperes printed on the serial plate. Actual ampere draw may be less Color Decsription Color than specified. Field wiring from the refrigeration control Ground Green panel to the merchandisers is required for refrigeration...
  • Page 17: Wiring Diagram Information

    3147479 Wiring Diagram Access A Wiring diagram was shipped with the case and packaged with this Installation Manual. If the diagram is missing or misplaced, please contact Hussmann (page 4 or 29) for an electronic version. Case Parameters and Setpoints...
  • Page 18 CA Warning August 31, 2018 This warning does not mean that Hussmann products will cause cancer or reproductive harm, or is in violation of any product-safety standards or requirements. As clarified by the California State government, Proposition 65 can be considered more of a ‘right to know’...
  • Page 19: Controller Operation Guide

    Danfoss Controller User Guide UserGuide Controller for temperature control AK-CC210 ADAP-KOOL® Refrigeration control systems Open Camera IPhone User Hold the camera up to the QR code Android User Open QR Code Reader app if necessary. Hold the camera up to the QR code Tap the notification to be taken to the destination of the QR code...
  • Page 20: Maintenance

    The drain is located under the deck pans. • DO NOT USE A CHLORINATED CLEANER ON ANY Hussmann recommends using a clean damp chamois, or a SURFACE. paper towel marked as “dust and abrasive free” with 210 Plastic ®...
  • Page 21: Service Information

    Service Tips WARNING ALWAYS DISCONNECT THE ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT OF THIS REFRIGERATOR. THIS INCLUDES, BUT IS NOT LIMITED TO SUCH ITEMS AS FANS AND THERMOSTATS. Fan Blade Replacement Service The evaporator fan is located directly under the deck pan. •...
  • Page 22: User Information

    Hussmann cases were not designed to “heat up” or “cool down” product - but rather to maintain an item’s proper temperature for maximum shelf life. To achieve the protection required always: 1.
  • Page 23: Trouble Shooting

    Trouble Shooting Condition Troubleshooting Water is on the Floor Caution! Water on flooring can cause much damage! Until cause is determined (and repaired), following these procedures: Use wet-dry vacuum (or mop & bucket) to remove standing water. Use 'catch pans' for water to drain into. Swap out regularly until case has completely drained.
  • Page 24 Trouble Shooting Continued Condition Troubleshooting Case is not Holding Check Merchandising Planogram / Observe Load Limits Temperature -Evenly distribute product as much as possible (Continued) -Avoid uneven stacking -Orient product on round ends or corner in a radial pattern in relation to the discharge air walls -Create a channel or path for discharge air to travel towards products at the edge of the merchandiser...
  • Page 25: Replacement Parts

    Replacement Parts TY3ECRC-3X4.5E-S TY3ECRC-3X5.5E-S TY3ECRC-4X6E-S TY3ECRC-5X7I-S COMPONENT / Spec Condensing Unit 3082674500 1H96225500 1H96254500 2H17034500 Evap Fan Motor 0527610 0527610 0527610 0527610 Evap Fan Blade CONTACT HUSSMANN PERFORMANCE PARTS Condensate Pan 1H95139550 1H95139550 1H95139550 1H95142550 Anti-Sweat Heater 0495007 0495007 0495007...
  • Page 26 Additional copies of this publication may be obtained by contacting: They can be found on a small metal plate on the unit. Hussmann® Chino Please note them below for future reference. 13770 Ramona Avenue • Chino, California 91710...