Finishing Touches; User Information - Hussmann Q1-FC Installation & Operation Manual

Single deck service seafood merchandiser
Table of Contents

Advertisement

Installing Splashguard
After merchandisers have been leveled and joined, and
all drip piping, electrical and refrigeration work has been
completed, install the splashguards. Splashguards may
be sealed to the floor using a vinyl cove base trim. The
size of trim needed will depend on how much the floor is
out of level.
Stocking
Improper temperature and lighting will cause serious
product loss. Discoloration, dehydration and spoilage
can be controlled with proper use of the equipment and
handling of product. Product temperature should always
be maintained at a constant and proper temperature.
This means that from the time the product is received,
through storage, preparation and display, the temperature
of the product must be controlled to maximize life of the
product. Hussmann cases were not designed to "heat up"
or "cool down" product - but rather to maintain an item's
proper temperature for maximum shelf life. To achieve the
protection required always:
1. Minimize processing time to avoid damaging
temperature rise to the product. Product should be
at proper temperature.
2. Keep the air in and around the case area free
of foreign gasses and fumes or food will rapidly
deteriorate.
3. Maintain the display merchandisers temperature
controls as outlined in the refrigerator section of this
manual.
4. Do not place any product into these refrigerators
until all controls have been adjusted and they
are operating at the proper temperature. Allow
merchandiser to operate a minimum of six (6) hours
before stocking with any product.
5. When stocking, never allow the product to extend
beyond the recommended load limit. Air discharge
and return air flow must be unobstructed at all times
to provide proper refrigeration.
6. There are vents located at the base of the front
of the glass, just above the front rail. These vents
supply a continuous, gentle flow of air across the
front glass which inhibits condensation. Do not
place any signs or other restrictive objects on the
front of the refrigerator that will block these vents.
7. Keep the service doors closed (when applicable).
Refrigeration performance will be seriously affected
if left open for a prolonged period of time.

8. Finishing Touches

NOTE:
1. Remove all dirt, wax, debris, etc. from the area of
2. Apply a good contact cement to the trim, allowing a
3. Install trim to the splashguard so that it is flush with

9. User Information

8. Avoid the use of supplemental flood or spot lighting.
9. In the Deli, Meat and Fish cases, completely cover
10. Turn and rotate the meat fairly often. The blood
11. Cold coils remove heat and moisture from the
Important Steps
1. Do not set temperature too cold, as this causes
2. Temperature control should be by means of a
3. Product should be worked and rotated on a regular
17
The splashguard must be removable to allow access to
components behind it.
the splashguard to ensure a secure adhesion.
proper dry time.
the floor.
Display light intensity has been designed for
maximum visibility and product life at the factory.
The use of higher output fluorescent lamps (H.O.
and V.H.O.), will shorten the shelf life of the product.
the product each night with a clean damp cloth or
butcher paper (never use plastic, as it does not
allow for proper circulation). Make sure the cloth or
paper is in direct contact with the product.
which gives the pink color works its way downward
with time.
case and deposit this as frost onto the coil. Thus,
a defrost is required. Our humidity system induces
moisture into the case and helps slow down the
dehydration process. The only other moisture within
the case is that in the product itself. A single level of
meat will dry out faster than a fully loaded case of
3-4 levels of meat.
product dehydration. Product Temperature:
33°-35°F! Set thermostat to cut in at 28°F discharge
air. Meat holding box: 32°F. Meat prep room: 55°F.
Meat bloom box: 36°F. Process the meat to enter
case at 40°F or below. Product deterioration is very
rapid above 40°F.
T-STAT and Suction Stop Solenoid at each case.
Do not use EPR valves, Liquid line solenoids or
electronic control devices of any kind, as these
allow temperature swings causing dehydration and
excessive energy consumption.
basis, not to exceed a 4 hour period.