ADTRAN OSU 300 User Manual
Hide thumbs Also See for OSU 300:
Table of Contents

Advertisement

Quick Links

61200663L1-1B
May 2001
OSU 300
User Manual
1200663L1
Single Mode SC
1200663L2
Multi-mode SC
1200663L4
Multi-mode ST
1200218L1
HSSI DTE Interface Card
1200219L1
V.35 DTE Interface Card
1200284L1
Quad DSX-1 Interface Card

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OSU 300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADTRAN OSU 300

  • Page 1 OSU 300 User Manual 1200663L1 Single Mode SC 1200663L2 Multi-mode SC 1200663L4 Multi-mode ST 1200218L1 HSSI DTE Interface Card 1200219L1 V.35 DTE Interface Card 1200284L1 Quad DSX-1 Interface Card 61200663L1-1B May 2001...
  • Page 2 OpenView is a trademark of Hewlett-Packard Company. Spectrum is a registered trademark of Cabletron. Netview is a registered trademark of IBM. 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35806 (256) 963-8000 © 2001 ADTRAN, Inc. All Rights Reserved. Printed in U.S.A.
  • Page 3 The following conventions are used in this manual. Notes provide additional useful information. Cautions signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equip- ment or endangerment to human life. Important Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: Do not use this product near water, such as near a bathtub, wash bowl, kitchen...
  • Page 4 Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A dig- ital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5 (including, but not limited to, loss of data or information, loss of profits, or loss of use). ADTRAN is not liable for damages for any cause whatso- ever (whether based in contract, tort, or otherwise) in excess of the amount paid for the item.
  • Page 6 Customer Service, Product Support Information, and Training ADTRAN will replace or repair this product within five years from the date of ship- ment if the product does not meet its published specification, or if it fails while in ser- vice.
  • Page 7 The Enterprise Network (EN) Technical Training Department offers training on our most popular products. These courses include overviews on product features and func- tions while covering applications of ADTRAN's product lines. ADTRAN provides a va- riety of training options, including customized training and courses taught at our facilities or at your site.
  • Page 8 viii...
  • Page 9: Table Of Contents

    DC Terminal Block......................2-5 DTE Ports 2-4 (Expansion Slots) ................. 2-5 DTE Port 1 (HSSI Interface) ..................2-6 Alarm Connector......................2-6 LAN Port ........................2-6 Optical Interface Port....................2-7 Single-Mode ......................2-7 Multi-Mode ......................2-7 61200663L1-1 OSU 300 User Manual...
  • Page 10 Powering the Unit ....................... 2-8 Reviewing the Front Panel ....................2-9 Control Port........................2-9 VT-100 Terminal Connection ................2-9 Navigating Within the Menus ................2-11 OSU 300 Main Menus ..................2-11 Status ......................2-11 Statistics ......................2-11 Configuration ....................2-11 Diagnostics ....................2-11 Remote Login ....................
  • Page 11 LC (loopback circuit C) ................. 4-6 TM (test mode) ....................4-6 V.35 Interface Leads ..................... 4-7 RS ........................4-7 CS ........................4-7 CD ........................4-7 TR ........................4-7 SR ........................4-7 LL ........................4-7 RL ........................4-7 TM ........................4-7 61200663L1-1 OSU 300 User Manual...
  • Page 12 Pattern ........................6-12 Invert Pattern ....................... 6-13 BERT Information Fields ..................6-13 Port ......................... 6-13 Direction ......................6-13 State ........................ 6-13 Errors ......................6-14 Current Err/Sec .................... 6-14 Insert Error ......................6-14 Clear Errors ......................6-14 OSU 300 User Manual 61200663L1-1...
  • Page 13 Fractional T3 Carrier Application ..................7-4 Remote SNMP Management Application ............... 7-6 Voice Application ........................ 7-7 Appendix A. Pinouts ....................... A-1 Appendix B. Specifications Summary ................B-1 Appendix C. Acronyms/Abbreviations................ C-1 Appendix D. Glossary ..................... D-1 Index ........................... Index-1 61200663L1-1 OSU 300 User Manual xiii...
  • Page 14 Table of Contents OSU 300 User Manual 61200663L1-1...
  • Page 15: List Of Figures

    List of Figures Figure 2-1. OSU 300 Rear Panel Description ..............2-4 Figure 2-2. Moving the Optical Interface Door .............. 2-4 Figure 2-3. DC Power Connector ..................2-5 Figure 2-4. OSU 300 Front Panel ..................2-9 Figure 2-5. OSU 300 Main Menu ..................2-10 Figure 3-1.
  • Page 16 Figure 6-18. BERT Pattern Menu ..................6-13 Figure 7-1. Single Port Application .................. 7-1 Figure 7-2. Multiport Application ..................7-3 Figure 7-3. Fractional Application..................7-5 Figure 7-4. Remote Management Application ............... 7-6 Figure 7-5. Voice Application.................... 7-7 OSU 300 User Manual 61200663L1-1...
  • Page 17 Fractional T3 Application Configuration Example ........7-5 Table 7-4. Configuration Example for Remote SNMP Management Application .. 7-6 Table 7-5. Local OSU 300 ....................7-6 Table 7-6. Configuration Example for a Voice Application ........7-7 Table A-1. Control Port Pin Assignments ..............A-1 Table A-2.
  • Page 18 List of Tables xviii OSU 300 User Manual 61200663L1-1...
  • Page 19: Chapter 1. Introduction

    The OSU 300 contains a built-in HSSI (high speed serial interface) port and three expansion slots which accept additional HSSI, V.35, or Quad DSX-1 interface cards. The HSSI interfaces support rates between 75 kbps and 44.2 Mbps in 75-kbps increments.
  • Page 20: Optical Interface Port

    SNMP, Telnet, or a VT-100 terminal interface. This connection can be made via Ethernet or a local EIA-232 link. The OSU 300 is designed for either desktop use or for installation in a 19-inch rack. The major features of the OSU 300 are as follows: •...
  • Page 21: Snmp

    (AUX) control port or the 10BaseT local area network (LAN) port. The OSU 300 supports the MIB-II standard, RFC 1213 and 1407, and the ADTRAN Enterprise Specific MIB. The term SNMP broadly refers to the message protocols used to...
  • Page 22: Telnet

    TELNET Telnet provides a password-protected, remote login facility to the OSU 300 that allows a remote user to control the OSU 300 through the terminal menus. Only one Telnet session may be active at a time.
  • Page 23: V.35 Card

    Quad DSX-1 Card The optional Quad DSX-1 interface card plugs into the card slots on the rear of the OSU 300. This card allows you to transport up to four DSX-1 lines per card over the DS3 interface of the OSU 300 along with high-speed data from the other HSSI/V.35 ports.
  • Page 24 Chapter 1. Introduction OSU 300 User Manual 61200663L1-1...
  • Page 25: Chapter 2. Installation And Operation

    Installation and Operation Chapter 2 RECEIVING INSPECTION Carefully inspect the OSU 300 for any damage that may have occurred in shipment. If damage is suspected, file a claim immediately with the carrier and contact ADTRAN Technical Support (see the last page of this manual). Keep the original shipping container to use for future shipment or verification of damage during shipment.
  • Page 26: Installing The Unit

    Chapter 2. Installation and Operation INSTALLING THE UNIT The OSU 300 can be used as a desktop stand-alone device or mounted into a standard 19-inch equipment rack. See the section VT-100 Terminal Connection on page 2-9 for information on terminal configuration.
  • Page 27: Desktop Installation

    Pin assignments for the connectors are given in Appendix A. Figure 2-1 on page 2-4 shows the OSU 300 rear panel, and Figure 2-2 on page 2-4 shows the movement of the optical interface door.
  • Page 28: Figure 2-1. Osu 300 Rear Panel Description

    Optical Interface DS3 service connection. Removable Dust Protects unit from dust. Remove to use the Optical Cover Interface. Figure 2-1. OSU 300 Rear Panel Description Slide this door up and down Laser Radiation Avoid Exposure to Beam to access the...
  • Page 29: Strain Relief

    (usually -48V). Figure 2-3. DC Power Connector DTE Ports 2-4 (Expansion Slots) The OSU 300 rear panel contains three expansion slots (DTE ports 2-4) for installing optional interface cards. Currently available cards include the HSSI card (P/N 1200218L1), the V.35 card (P/N 1200219L1), and the Quad DSX-1 card (P/N 1200284L1).
  • Page 30: Dte Port 1 (Hssi Interface)

    The alarm connector is a three-position, screw-type terminal block that connects to the three contacts of a Form C-type relay on the main board of the OSU 300. This relay activates any time the OSU 300 detects an alarm condition on the high-speed network interface.
  • Page 31: Optical Interface Port

    Chapter 2. Installation and Operation Optical Interface Port The OSU 300 optical interface port consists of a single-mode or multi-mode transceiver module composed of a transmitter, a receiver, and an SC or ST receptacle. The optical interface port supports angled SC type optical connectors (61200663L1 and L2 only) and operates in the 1280 nm to 1335 nm wavelength range (1310 nm nominal).
  • Page 32: Powering The Unit

    Chapter 2. Installation and Operation The OSU 300 comes with a removable process plug that covers the optical interface. A mechanical door engages when the fiber cable is removed from the optical interface (see also, Figure 2-2 on page 2-4). This door protects the unit from dust in the event of the optical interface being disconnected, and it provides additional protection for the human eye from the laser beam.
  • Page 33: Reviewing The Front Panel

    Chapter 2. Installation and Operation REVIEWING THE FRONT PANEL Figure 2-4 illustrates the OSU 300 front panel. Descriptions of each front panel item follow Figure 2-4. OSU 300 CONTROL REMOTE STATUS STATUS STATUS IN SERVICE STATUS ACTIVE IN TEST IN TEST...
  • Page 34: Figure 2-5. Osu 300 Main Menu

    Press repeatedly until the password prompt appears. Enter Enter the password. The factory default password is adtran (all lower-case). The M menu appears (see Figure 2-5). Make selections by entering the number corresponding to the chosen parameter. Press to return to the previous screen.
  • Page 35: Navigating Within The Menus

    Chapter 2. Installation and Operation Navigating Within the Menus Navigate within the OSU 300 terminal menus using the following procedures: If you want to... Press... select an item the number corresponding to your choice, and then press the Enter key.
  • Page 36: Remote Login

    Remote Active LED A solid LED indicates a remote configuration session is taking place through a Telnet session or from the remote end OSU 300. The LED flashes when the unit is being accessed locally through the front panel port.
  • Page 37: Dte Port Leds

    In Test This LED indicates the DTE interface is performing a BERT test. This LED indicates the OSU 300 DTE port is transmitting data. This LED indicates the OSU 300 DTE port is receiving data. 61200663L1-1 OSU 300 User Manual...
  • Page 38 Chapter 2. Installation and Operation 2-14 OSU 300 User Manual 61200663L1-1...
  • Page 39: Figure 3-1. Configuration Main Menu

    Configuration Chapter 3 The OSU 300 can be configured locally and remotely. Local configuration is accomplished through a 10BaseT Ethernet connection, a SLIP/PPP port, or a VT-100 terminal. Remote configuration can take place through the T3 data link using a local OSU 300.
  • Page 40: Chapter 3. Configuration Ds3 Network

    Chapter 3. Configuration DS3 NETWORK To access the network configuration parameters, select 1- DS3 . Configure the OSU 300 network settings to match the T3 ETWORK signal received from the service provider. During remote configuration, this menu is read-only. The DS3 N ETWORK menu is shown in Figure 3-2.
  • Page 41: Multiplexing Mode

    Configuration selections for the individual ports are described in the following section. A more in-depth description of T IMED is on page 3-10. ROFILES Figure 3-3. DTE Ports Menu 61200663L1-1 OSU 300 User Manual...
  • Page 42: Port Selections 1-4

    Table 3-2 on page 3-6 lists menu fields available only for V.35 interfaces. • Table 3-3 on page 3-8 lists the menu fields available for Quad DSX-1 interfaces. Figure 3-4. Port Configuration Menus for V.35 and HSSI Interface Cards OSU 300 User Manual 61200663L1-1...
  • Page 43: Configuration Selections For Hssi And V.35 Interfaces

    Mbps). Changes to this field do not take effect until PPLY ETTINGS is selected. This read-only status field shows the amount of bandwidth that will be ANDWIDTH available if the selection made in the field is applied. LOCKS 61200663L1-1 OSU 300 User Manual...
  • Page 44: Table 3-2. Additional V.35 Interface Port Configuration Selections

    Select this field after making all configuration changes for the selected PPLY ETTINGS port. The changes are then applied to the unit immediately. Applying the settings briefly affects all ports of the OSU 300. You may cancel changes made to the current menu by pressing ONFIGURATION the ESC key.
  • Page 45: Transmit Clock

    Chapter 3. Configuration Table 3-2. Additional V.35 Interface Port Configuration Selections (Continued) ELECTION ESCRIPTION The SR lead remains on except when the OSU 300 is executing a test. The SR lead remains on except when the unit receives an OOS/OOF OOS/OOF condition from the network or when the unit is executing a test.
  • Page 46: Configuration Selections For Dsx-1 Interfaces

    NSTALLED 1 interface. Displays the amount of bandwidth (in 75k increments) not already NALLOCATED allocated to any of the OSU 300 DTE ports. LOCKS If an individual DSX-1 interface is installed but not currently in use, set TATE . Set to to activate a port.
  • Page 47 STUFFING Set the line length for each DSX-1 interface according to the distance ENGTH from the OSU 300 to your DTE device. Set to 7.5 dB if the attached DTE device only supports DS-1 levels. DSX-1 T For each Quad DSX-1 card pair (the near-end and far-end Quad IMING DSX-1 cards), there must be only one source of timing.
  • Page 48: Timed Profiles

    For example, you can assign more bandwidth to the corporate LAN during business hours and more bandwidth to a backup machine in the evenings. The OSU 300 can store two separate user profiles which have bandwidth selections for each of the four ports.
  • Page 49: Profile Switch Time (1 And 2)

    (see Figure 3-8 on page 3-12) YSTEM ANAGEMENT allow you to configure the OSU 300 for management through SNMP, Telnet, or a VT-100 interface. Embedded SNMP and Telnet are available through either a SLIP/PPP or a 10BaseT Ethernet port.
  • Page 50: Local Ip Address

    Chapter 3. Configuration Figure 3-8. System Management Configuration Menu Local IP Address Enter the OSU 300 IP address. This IP address applies to the Ethernet or auxiliary port (when configured for PPP or SLIP). This address is available from the network administrator.
  • Page 51: Write Community Name

    Enter the authentication strings used for SNMP management. Match the OSU 300 to the SNMP manager for trap privileges. Trap IP Addresses Enter up to five SNMP manager IP addresses to which the OSU 300 sends traps. Trap Generation This field determines which trap types (if any) are generated by the unit (see Figure 3-9).
  • Page 52: Table 3-4. Near End Alarm Trap Descriptions

    FEAC channel of a service-affecting failure in the network equipment. Com. Eqpt. Fail when the unit receives indication from the network through the FEAC channel of a non-service-affecting failure in the network common equipment. 3-14 OSU 300 User Manual 61200663L1-1...
  • Page 53: Toggle All Traps

    THIS TRAP IS SENT QDSX Alarms when any of the DSX-1 ports detects an error condition. Toggle All Traps When activated, this entry allows you to toggle ALL alarms (previously described) between their disabled and enabled states. 61200663L1-1 OSU 300 User Manual 3-15...
  • Page 54: Password

    Chapter 3. Configuration Password Set the password required at login (up to 32 characters). The default password is adtran (all lower case). Terminal Timeout Set the amount of time the terminal or Telnet session can remain inactive before requiring re-entry of the password for access. This...
  • Page 55: Date/Time

    If enabled, the alarm circuit is activated when a network alarm occurs. UTILITIES The U menu allows you to view OSU 300 system TILITIES information (including self-test results), revert to default configuration settings, or flash load a new version of software. The...
  • Page 56: Save Configuration

    TEST RESULTS ARE PASS the self-test was successful and the unit is ready to use. BAD RAM DATA contact ADTRAN Technical Support. See Customer Service, Product Support Information, and Training in BAD RAM ADDRESS the front section of this manual. BAD CHECKSUM...
  • Page 57: Chapter 4. Status

    Chapter 4 View port status information by selecting 1-S from the M TATUS menu. Information for the network port and the DTE ports is provided. Figure 4-1 shows the S menu. TATUS Figure 4-1. Status Menu 61200663L1-1 OSU 300 User Manual...
  • Page 58: Network: State

    The unit is currently in test mode. The menu provides IAGNOSTICS information on test type. NETWORK: ALARM This field displays the current alarm condition of the OSU 300. Possible conditions are given in the following chart. Condition Description Normal No alarms are currently being received.
  • Page 59: Remote Status: Alarm

    The network has signaled a non-service affecting common equipment failure condition. Unknown The OSU 300 is unable to determine the state of the network or the remote unit. REMOTE STATUS: DATA LINK This field displays the current state of the data link between the remote and the local OSU 300s.
  • Page 60: Dte Ports

    Quad DSX-1 interface card. DTE Leads If a lead is active on the port, it displays in this field. The leads differ according to the interface type. This field does not apply to OSU 300 User Manual 61200663L1-1...
  • Page 61: T1 Status

    The Quad DSX-1 interface card has just been inserted and is initializing. Comm Error The OSU 300 unit is unable to communicate with the Quad DSX-1 interface card. If displayed, call ADTRAN Technical Support (refer to the last page of this manual).
  • Page 62: Hssi Interface Leads

    Asserted by the unit to request a loopback from the DTE. TM (test mode) Asserted by the OSU 300 when either the network or the port is being tested. Both TA and CA must be on before data will flow.
  • Page 63: V.35 Interface Leads

    Clear to send. Carrier detect. Data terminal ready. Data set ready. Local DTE port loopback. Remote port payload loopback. Test mode. Asserted by the OSU 300 when either the network or the port is being tested. 61200663L1-1 OSU 300 User Manual...
  • Page 64 Chapter 4. Status OSU 300 User Manual 61200663L1-1...
  • Page 65: Chapter 5. Statistics

    5-1). If a Quad DSX-1 card is installed, the menu item O THER appears on the main S screen. This selection TATISTICS TATISTICS provides access to alarm counts for the DSX-1 ports. Figure 5-1. Main Local Statistics Menu Screen 61200663L1-1 OSU 300 User Manual...
  • Page 66: Alarm History

    ONFIGURATION ETWORK Alarm History The OSU 300 keeps track of yellow and red alarms for the near end. View alarm history information in one of the three time period selections, or view a cumulative alarm count. Information in these fields is for the given time period (if any) since the last reset. The...
  • Page 67: Figure 5-2. Current Alarm Count

    When a > or < symbol appears in the upper corner of the screen, you can use the arrow keys on your keyboard to scroll right or left to view addi- tional information (see Figure 5-3 above). 61200663L1-1 OSU 300 User Manual...
  • Page 68: Performance Parameters

    Information in these fields is for the given time period since the last reset. When viewing the 24-hour history statistics screen, use the left and right arrow keys to scroll through all 96 15-minute intervals. See Figures 5-6 through 5-8 for examples OSU 300 User Manual 61200663L1-1...
  • Page 69: Figure 5-6. Network Statistics Menu For Current 15-Minute Interval

    Chapter 5. Statistics of the performance parameter screens. Descriptions of each field on these screens follow the illustrations. Figure 5-6. Network Statistics Menu for Current 15-Minute Interval Figure 5-7. Network Port Statistics 24-Hour History 61200663L1-1 OSU 300 User Manual...
  • Page 70: Figure 5-8. Network Port Statistics Menu (24-Hour Totals)

    Number of seconds in which one or more CVs or one or more LOS (loss of signal) defects occurred. P-Bit Errored Seconds (PES) Number of seconds with one or more PCVs (P-bit coding violations), one or more out of frame defects, or a detected OSU 300 User Manual 61200663L1-1...
  • Page 71 Time that the network port is available for data delivery. Clear All Local DS3 Statistics/Refresh All Remote Statistics Clears or refreshes all current information. These selections affect all statistical information (not just the displayed screen). 61200663L1-1 OSU 300 User Manual...
  • Page 72 Chapter 5. Statistics OSU 300 User Manual 61200663L1-1...
  • Page 73: Chapter 6. Diagnostics

    The D menu allows you to initiate loopback and BERT IAGNOSTICS tests from the OSU 300. Figure 6-1 on page 6-2 shows the main menu. Perform tests for the entire DS3 or for an IAGNOSTICS individual DTE port. If a Quad DSX-1 card is installed, activate loopback tests for an entire card (all four DSX-1s) or for an individual DSX-1 port.
  • Page 74: Ds3

    When you access the DS3’s diagnostic options by selecting 1 from the main D menu, the screen shown in Figure 6-2 IAGNOSTICS displays. Figure 6-2. DS3 Diagnostics Menu Data Mode Ends a test already in progress for this port. OSU 300 User Manual 61200663L1-1...
  • Page 75: Ds3 Payload Loopback

    This selection initiates a DS3 loopback test for the remote unit and sends/checks the BERT pattern over the entire DS3 payload bandwidth. DTE Ports 1-4 Access the DTE port diagnostic options by selecting the number corresponding with the desired port (options 2 through 5) from the 61200663L1-1 OSU 300 User Manual...
  • Page 76: Hssi And V.35 Diagnostic Options

    Perform this test to verify the integrity of the portion of the DS3 link connecting the selected port of the OSU 300 and the remote DTE. This test is non- intrusive to the three other ports (see Figure 6-5 on page 6-5).
  • Page 77: Payload Bert

    Figure 6-6. Payload BERT Test DTE Loopback This test is used to verify proper operation of the link between the OSU 300 and the terminal equipment. During this test, all data sent by the terminal equipment is looped back to the terminal 61200663L1-1...
  • Page 78: Payload And Dte Loopback

    Select this test to perform payload and DTE loopbacks simultaneously. The individual tests are described on page 6-3 and page 6-5, respectively. Figure 6-8 shows a block diagram illustrating this test. OSU 300 Figure 6-8. Payload and DTE Loopback Test OSU 300 User Manual 61200663L1-1...
  • Page 79: Remote Port Payload Loopback

    Perform this test to verify the integrity of the portion of the DS3 link connecting the local DTE and the selected port of the remote OSU 300. All other ports on both the local and remote units are unaffected.
  • Page 80: Payload Loopback

    During this test, all information from the network side (DS3) for the selected DSX-1 interface is looped back towards the network. See Figure 6-11 for an illustration of this test. OSU 300 Quad DSX-1 DSX-1 DS3 MUX Figure 6-11. Framer Loopback Test OSU 300 User Manual 61200663L1-1...
  • Page 81: Local Loopback

    During this test, all information on the selected DSX-1 interface, including framing, is looped back towards the DTE. See Figure 6-13 for an illustration of this test. OSU 300 Quad DSX-1 DSX-1 DS3 MUX Figure 6-13. Line Loopback Test 61200663L1-1 OSU 300 User Manual...
  • Page 82: Payload Loopback

    Figure 6-14. Payload Loopback Test DTE Loopback During this test, the combined information from the four DSX-1 interfaces is locally looped at the multiplexer of the OSU 300 back towards the Quad DSX-1 interface card. The end result of this test is 6-10...
  • Page 83: Payload And Dte Loopback

    6-16 for an illustration of this test. OSU 300 OSU 300 Quad DSX-1 Quad DSX-1 DS3 MUX DS3 MUX DSX-1 DSX-1 Port in Payload Unit in Data Mode and DTE Loopback Figure 6-16. Payload and DTE Loopback Test 61200663L1-1 OSU 300 User Manual 6-11...
  • Page 84: Remote Port And Payload Loopback

    • All zeros • 2^15-1 • All ones • 2^23-1 The test pattern is used to independently test the operation of the framing circuitry and the network interface of the OSU 300. Instead 6-12 OSU 300 User Manual 61200663L1-1...
  • Page 85: Invert Pattern

    OSU 300’s internal test pattern generator and detector. Figure 6-18. BERT Pattern Menu Invert Pattern If set to E , the OSU 300 inverts the transmitted and received NABLE BERT test pattern. This allows the unit to be compatible with test equipment which generates inverted BERT patterns.
  • Page 86: Errors

    Chapter 6. Diagnostics Errors Displays the number of BERT errors received by the OSU 300 since the last reset. Current Err/Sec Displays the number of BERT errors received by the unit in the last second. Insert Error Inserts one error into the data stream.
  • Page 87: Chapter 7. Applications

    44.2 Mbps data over unchannelized T3 circuits. In the application shown in Figure 7-1, the OSU 300 provides network connectivity for a router running at 44.2 Mbps. The data is frame relay and the unit is SNMP-managed via the local Ethernet.
  • Page 88: Point-To-Point Multiport Application

    When networking requirements call for sharing the bandwidth of a point-to-point T3 circuit, additional data ports can be installed into the OSU 300 for multiport operation. The OSU 300 supports up to three port option cards (Quad DSX-1, V.35 or HSSI). These option cards are hot-swappable and can be field installed.
  • Page 89: Figure 7-2. Multiport Application

    Chapter 7. Applications The bandwidth is split by the OSU 300 to provide 18 Mbps for each router, 1.5 Mbps for the video conference units, and 6 Mbps for the main frames. See Table 7-2 for an example configuration of this application.
  • Page 90: Fractional T3 Carrier Application

    FRACTIONAL T3 CARRIER APPLICATION When network providers want to provide service at rates less than full T3, OSU 300 units can be used in pairs for deploying sub-T3 rate services. In this application example (shown in Figure 7-3 on page 7-5), a carrier provides fractional T3 access at 8 Mbps for internet connectivity.
  • Page 91: Figure 7-3. Fractional Application

    Nothing required. Remote unit Management can be managed using the lo- Subnet Mask - 255.255.255.0 cal OSU 300. Gateway IP Address - 12.6.12.1 IP Security - Disabled Trap IP Address - 12.6.12.10 Management Port - LAN 61200663L1-1 OSU 300 User Manual...
  • Page 92: Remote Snmp Management Application

    Chapter 7. Applications REMOTE SNMP MANAGEMENT APPLICATION A remote OSU 300 can be managed by a local management station if the remote unit is assigned its own IP address. This address must be assigned at both the near and far ends. Also, the D option must be enabled on both units.
  • Page 93: Voice Application

    Port State - Enabled Port State - Enabled Nx75k blocks - 240 Nx75k blocks - 240 DTE 2 (HSSI) Port State - Enabled Port State - Enabled Nx75k blocks - 80 Nx75k blocks - 80 61200663L1-1 OSU 300 User Manual...
  • Page 94 Nothing required. Remote unit Management can be managed using the lo- Subnet Mask - 255.255.255.0 cal OSU 300. Gateway IP Address - 10.4.10.1 IP Security - Disabled Trap IP Address - 10.4.10.10 Management Port - LAN OSU 300 User Manual 61200663L1-1...
  • Page 95: Appendix A. Pinouts

    Pinouts Appendix A The following tables give the pin assignments for the connectors located on the OSU 300. For more information on these connectors, see the chapter Installation and Operation on page 2-1. Table A-1. Control Port Pin Assignments RJ Pin#...
  • Page 96: Table A-2. Hssi Interface Pin Assignments

    Loopback Circuit A (LA) Send Data (SD) Loopback Circuit B (LB) Signal Ground (SG) 14-18 39-43 Five Ancillary to DCE Signal Ground (SG) 20-23 45-48 Five Ancillary from DCE Test Mode (TM) Signal Ground (SG) OSU 300 User Manual 61200663L1-1...
  • Page 97: Table A-3. Lan Port Pin Assignments

    Description Protective Ground (PG) Signal Ground (SG) Request to Send (RTS) Clear to Send (CTS) Data Set Ready Received Line Signal Detector (CD) – Data Terminal Ready (DTR) – not used – Local Loopback (LL) 61200663L1-1 OSU 300 User Manual...
  • Page 98: Table A-5. Quad Dsx-1 Interface Card Pin Assignments

    Table A-5. Quad DSX-1 Interface Card Pin Assignments Name Description R1 TXDATA-RING Send data toward DTE T1 TXDATA-TIP Send data toward DTE UNUSED – R RXDATA-RING Receive data from DTE T RXDATA-TIP Receive data from DTE 6,7,8 UNUSED – OSU 300 User Manual 61200663L1-1...
  • Page 99: Appendix B. Specifications Summary

    Specifications Summary Appendix B SPECIFICATIONS AND FEATURES This section describes the standard specifications and features incorporated into the OSU 300. Optical Interface Clear channel, non-channelized DS3. Line length: Single-mode (40 Km); multi-mode (2 Km). Framing format: M13 and C-bit parity.
  • Page 100 Remote configuration and statistics access available inband. SNMP/Telnet Integrated 10BaseT Ethernet and SLIP/PPP (async) port. MIB II, RFC 1213 and 1407 compliant. ADTRAN Enterprise MIB for extended monitoring and control/ configuration. Agency Approvals FCC Part 15, Class A, UL and CUL Environment Operating: 0 to 50 °C (32 to 122 °F)
  • Page 101: Appendix C. Acronyms/Abbreviations

    CSU ....channel service unit CTS....clear to send dB....... decibel DCD ....data carrier detect data communications equipment DCE ....DDS....digital data service DLCI ....data link connection identifier DSR ....data set ready 61200663L1-1 OSU 300 User Manual...
  • Page 102 MIB....management information base ms....... millisecond NC...... normally closed NI ....... network interface NMS ....network management system NO ..... normally open NRZ ....non-return to zero OCU....office channel unit OOF ....out of frame OSU 300 User Manual 61200663L1-1...
  • Page 103 ....synchronous TA ...... terminal equipment available TD...... transmit data time division multiplexing TDM....TM ..... test mode TR ...... data terminal ready Tx ....... transmit UAS ....unavailable seconds wide area network WAN....61200663L1-1 OSU 300 User Manual...
  • Page 104 Appendix C. Acronyms/Abbreviations OSU 300 User Manual 61200663L1-1...
  • Page 105: Appendix D. Glossary

    The bandwidth determines the rate at which information can be sent through a channel (the greater the bandwidth, the more information that can be sent in a given amount of time). 61200663L1-1 OSU 300 User Manual...
  • Page 106 T3 operates at 44.736 Mbps. bipolar violation. A violation in the alternate mark inversion line code for which consecutive 1s are represented by pulses of opposite polarity. BPVs that are not OSU 300 User Manual 61200663L1-1...
  • Page 107 The channel bank also detects and transmits signaling information for each channel, thereby transmitting framing information so that time slots allocated to each channel can be identified by the receiver. 61200663L1-1 OSU 300 User Manual...
  • Page 108 (2) to provide a time base. control port The electrical interface between the OSU 300 and the control terminal. The con- trol terminal is used to communicate commands to the unit. customer premise equipment. All telecommunications terminal equipment...
  • Page 109 1.544 Mbps). digital signal level three. Equivalent of 28 DS1s and 672 DS0s (total bandwidth is 44.736 Mbps). data service unit. A device designed to transmit and receive digital data on digi- tal transmission facilities. 61200663L1-1 OSU 300 User Manual...
  • Page 110 TV, wire, satel- lite, and cable. facility datalink. FDL bits provide overhead communication between the termi- nal equipment in ESF framing. gateway A device which enables information to be exchanged between two dissimilar systems or networks. OSU 300 User Manual 61200663L1-1...
  • Page 111 Defined as a line state in which no pulses are received for 175 bit positions. DS1/DS3 multiplexer that combines up to 28 DS1 channels into one DS3 chan- nel. Uses two-stage, bit synchronous TDM. Mbps Megabits per second (one million bits per second). 61200663L1-1 OSU 300 User Manual...
  • Page 112 1 bit, and does not return to zero between successive 1 bits. out-of-band Signaling that is separated from the channel carrying information (voice, data, video, etc.). Typically the separation is accomplished by a filter. The signaling includes dialing and other supervisory signals. OSU 300 User Manual 61200663L1-1...
  • Page 113 LOS or OOF not caused by an alarm indication signal (AIS) that persists for more than two seconds. remote configuration A feature designed into ADTRAN products that allows remote units to be con- figured from a local unit or a VT 100 compatible terminal. router A device that supports communications between networks.
  • Page 114 Transmission rates of 1.544 Mbps are available on T1 communication lines. Also referred to as digital signal level 1 (DS-1). See also E1. Transmission rates of 44.736 Mbps are available on T3 communication lines. Also referred to as digital signal level 3 (DS-3). D-10 OSU 300 User Manual 61200663L1-1...
  • Page 115 VT 100 A non-intelligent terminal or terminal emulation mode used for asynchronous communications. Used to configure the OSU 300. wide area network. A communications network serving geographically separate areas. A WAN typically extends a LAN outside the building to link to other LANs over telephone lines.
  • Page 116 Appendix D. Glossary D-12 OSU 300 User Manual 61200663L1-1...
  • Page 117 3-7 auth failure traps 3-15 normal 3-7 auxiliary port 1-3 source 3-7 cold start traps 3-15 Com Eqpt Fail (NSA) 4-3 bad boot sector 3-18 common equipment fail NSA 3-14 bad checksum 3-18 61200663L1-1 OSU 300 User Manual Index-1...
  • Page 118 Quad DSX-1 6-1 far end alarm 3-13 DS3 6-1 far end alarm traps 3-14 diagnostics 6-2 FBE 5-7 interface 2-7 F-bit errors 5-7 network 3-1 FCC regulations, iv payload loopback 6-3 flash load 3-17 Index-2 OSU 300 User Manual 61200663L1-1...
  • Page 119 3-13 IP hosts 3-16 near end alarm trap 3-14 IP security 3-16 network 3-2 alarm 4-2 LEDs 2-12 LA 4-6 manager 1-3 LAN 1-3 port, status information 4-2 pin assignments A-3 test 3-13 61200663L1-1 OSU 300 User Manual Index-3...
  • Page 120 2-12 port bandwidth 3-5 payload loopback with BERT test 6-3 port state 3-5 port payload loopback test 6-7 port status 4-4 SNMP application 7-6 power up state 4-3 AC version 2-8 remote status Index-4 OSU 300 User Manual 61200663L1-1...
  • Page 121 TD LED 2-13 warranty, v TDM 1-1 write community name 3-13 technical support vi TELNET 1-1 2-12 3-11 3-16 terminal interface 3-1 yellow alarm 4-2 terminal timeout 3-16 yellow alarm traps 3-14 test patterns 6-12 61200663L1-1 OSU 300 User Manual Index-5...
  • Page 122: Index

    Index Index-6 OSU 300 User Manual 61200663L1-1...

This manual is also suitable for:

1200663l11200663l21200663l41200218l11200219l11200284l1

Table of Contents