20l smart dehumidifier
Hide thumbs Also See for DC20DE:

Advertisement

Functions
Note: Use the UP and DOWN buttons to set the humidity or set the device to the CO
or AU setting. These codes will show on the display when in the respective setting.
See below for the functionality of these settings.
Dehumidify Function
• When the CONTINUOUS ('CO') operation is set with DEHUMIDIFY (DEH), the
dehumidifier will continue to operate regardless of the humidity level.
• If the indoor humidity is higher than or equal to 3% more than the set humidity,
the compressor and fan will automatically begin to run. The indicator light of the
compressor will be on. When the humidity drops below 2% of the set humidity,
the compressor turns off and the dehumidifying function stops.The indicator light
next to 'OK' will turn on. The above functions work in a cycle, and the device will
automatically adapt to the surroundings. This allows the indoor humidity levels to
be maintained at the set humidity.
• When using the device in the COMFORT ('AU') setting, if the room temperature is
below 5°C, the dehumidifier will stop. If the room temperature is between 5-20°C, the
device will automatically set to 60% humidity. If the room temperature is between
20-27°C, the device will automatically set to 55% humidity. If the room temperature
is above 27°C, the device will automatically set to 50% humidity.
Dry Function
• When the CONTINUOUS ('CO') setting is set with DRY (Laundry), the dehumidifier
will continue to operate regardless of the humidity level.
• The fan speed will automatically lock at high speed. This cannot be adjusted whilst
DRY mode is in operation.
Fan Function
• When the FAN is running, the compressor will not work.
• There are two fan speed settings, being high and low.
• The Humidity setting button cannot be pressed in fan mode.
Full Water Protection
• When the water is full, the full water indicator will switch on (FULL) and a buzzer
will ring 15 times. Press any key to stop the buzzer. All controls will stop working
and functions will turn off.
• After emptying the tank, the device will restore the original operation status before
it switched off and the compressor will begin to run again after 3 minutes.
• Follow the instructions on page 18 to empty the full tank.