Summary of Contents for Dimplex DC20DE

  • Page 1 INSTRUCTION MANUAL 20L Smart Dehumidifier Models: DC20DE For domestic household use only.
  • Page 2 IMPORTANT THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Note also the information presented on the appliance DETAILS OF TYPE AND RATING OF FUSES : T; 3.15A; 250VAC. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/ OR DAMAGE AND MAY INVALIDATE YOUR WARRANTY Please read the operating instructions carefully before using your dehumidifier for the first time and keep them in a safe place.
  • Page 3 from traffic areas and where it will not be a tripping hazard. DO NOT COVER. Never cover or obstruct in any way the outlet at the top of the • dehumidifier or the air inlet slots at the rear of the dehumidifier. Only operate this appliance with a minimum of 50cm clearance all around i.e.
  • Page 4 WARNING: For using R290 refrigerant. ThIs symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. CAUTION: RISK OF FIRE/FLAMMABLE MATERIALS. THE APPLIANCE MUST BE INSTALLED, USED &...
  • Page 5 1. Transport of equipment containing flammable refrigerants - see transport regulations 2. Marking of equipment using signs - see local regulations 3. Disposal of equipment using flammable refrigerants - see national regulations. 4. Storage of equipment/appliances - The storage of equipment should be in accordance with the manufacturer's instructions.
  • Page 6 • Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance.
  • Page 7 • Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere.
  • Page 8 • Charging procedures In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright.
  • Page 9 • Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available.
  • Page 10 Exposed to the Near water If the power cable weather outdoors wires are frayed or cut Where small children If an extension Where the power may be left unattended lead may become cable may be overloaded damaged On a slope or Where there is risk Where it may be uneven surface...
  • Page 11: Specification

    Specification Model no. DC20DE Power supply 220-240V~, 50Hz Dehumidification capacity at 32°C, 80% RH 20L/day Air volume (max.) 200m3/h Noise level (max.) 48dB(A) Refrigerant R290 Water tank Size (WxDxH) mm 371 x 251 x 595mm N.W. kg 14kg Note. When the dehumidifier is in operation, the running compressor will produce heat, this is normal and...
  • Page 12: How It Works

    How It Works This product is a dehumidifier. It controls relative humidity by passing the air through the unit, forcing the excess moisture to condensate over the cooling elements. Contact with this cold surface causes the moisture in the air to condense. This condensed water then drains safely into the water tank.
  • Page 13 Parts Control Panel Rear Housing Air Inlet/Outlet Condensation Drain Hole Power Cord Water Tank Air Outlet Flap Air Outlet Front Housing Water Level Indicator Wheels...
  • Page 14: Control Panel

    Control Panel Operation 1. Press the POWER button to turn the unit On or Off. After it is switched on, the dehumidifying function will start immediately. The power indicator light next to 'DEH' will light up. When the compressor stops, the light will flash. 2.
  • Page 15 Operation light will switch and stay on if it successfully connects. The Glen Dimplex Connect phone app will allow for device functions to be controlled through the app as well. Please follow the included Wi-Fi instructions/app prompts to work this.
  • Page 16 Functions Note: Use the UP and DOWN buttons to set the humidity or set the device to the CO or AU setting. These codes will show on the display when in the respective setting. See below for the functionality of these settings. Dehumidify Function •...
  • Page 17 WiFi. • If the WiFi indicator light switches on and stays on, this means the device has succesfully connected to WiFi. • Further follow prompts from the WiFi instructions and Glen Dimplex Connect App to utilise this function.
  • Page 18 Drainage Note: When the water tank is full, the full tank indicator light will switch on and a buzzer will ring 15 times to alert that drainage needs to occur. Note: Do not remove the floater in the water tank, otherwise the water sensor will not be able to sense the water level and the device will not be able to operate normally.
  • Page 19 Drainage 3. Place the tank back into the unit by pressing the tank tightly with both hands, and placing into the slot. Continuous Drainage This device has a continuous drainage hole. Insert a plastic tube (not included) (10mm diameter) into the partition drainage hole as per below, and ensure it is sticking out from the tank side.
  • Page 20 Cleaning Body Cleaning Wipe the body of the unit with a soft, damp cloth. Filter Cleaning 1. Pull the filter up as per below. 2. To clean, use a vacuum cleaner to gently absorb any dust accumulation on the filter screen surface.
  • Page 21 Cleaning 3. To install the filter back in place, insert into the unit, and push the two hooks of the filter into place as shown below. Storage If planning to not use the unit for an extended period of time, please ensure: - There is no water in the tank - The power cord is rolled up - The unit is placed in a cool, dry place...
  • Page 22: Troubleshooting

    Trouble shooting THE UNIT DOES NOT OPERATE: • Is the unit plugged in? • Is the water tank indicator light on? • Is the room temperature above 35°C or below 5°C? • Ensure the plug and socket are connected well. •...
  • Page 24 Supplied by Glen Dimplex Australia 1340 Ferntree Gully Road, Scoresby, Victoria, 3179 © Glen Dimplex Australia. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex Australia.