MW-520 Application Developer's Guide
Table 4
HWDRIVER Parameters
Parameter
ShutdownTime*
CCFLPollingEnable
IgnitionOffEnable
CurrentStateDelay
Data
Description
0×03
Duration of shutdown process
(in case of critical CCFL
temperature). This value does
not exist in Windows 2000.
0×01
This parameter indicates
whether the MWService module
must perform MW-520 display
temperature polling. It also
enables/disables registration for
brightness up and brightness
down events. If the value of this
parameter is 1, display
temperature polling and
registration for brightness
events are enabled, otherwise,
they are disabled.
0×01
This parameter indicates
whether registration for ignition
power key off event is enabled.
If the value of this parameter
is 1, registration is enabled,
otherwise, it is disabled.
0×078
This parameter is used by the
MWDLL module only. When an
emergency event occurs,
MWDLL saves information
about it in its internal variable.
CurrentStateDelay is a period of
time (in seconds) during which
MWDLL keeps the emergency
state since the last time
emergency event occurred. If,
during this period of time, a new
client registers for an
emergency event, MWDLL
sends it a notification message
about the emergency event. If
CurrentStateDelay expires,
MWDLL does not send
emergency notification message
to new registered clients.