Heat-N-Glo TIARA I-CE Installer's Manual page 25

Table of Contents

Advertisement

1. Attach the flashing
and apply sealant
around the edges of
the flashing base.
2. Attach the storm
collar over the
flashing joint and
apply sealant be-
tween the storm
collar and vertical
pipe.
To seal the roof hole, and to divert rain and snow
from the flue system:
• Attach a flashing to the roof using nails, and use a
non-hardening mastic around the edges of the
flashing base where it meets the roof.
• Attach a storm collar over the flashing joint to
form a water-tight seal. Place non-hardening
mastic around the joint, between the storm collar
and the vertical pipe.
• Slide the termination cap over the end of the flue
pipe and rotate the pipe clockwise 1/4 turn.
61cm
61cm
LOWEST
DISCHARGE
OPENING
TERMINATION
CAP
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Roof Pitch
flat to 6/12
6/12 to 7/12
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
over 14/12 to 16/12
over 16/12 to 18/12
over 18/12 to 20/12
over 20/12 to 21/12
Figure 21. Minimum Height from Roof to Lowest
Discharge Opening
HORIZONTAL
OVERHANG
VERTICAL WALL
X
12
ROOF PITCH IS X/ 12
H (min.) cm
30.5
38
45.75
61
76.25
99
122
152.5
183
213.5
228.75
244
29