Heat-N-Glo TIARA I-CE Installer's Manual page 12

Table of Contents

Advertisement

STRAIGHT VERTICAL FLUEING
When a vertical run of 4 meters and higher is attached directly to the top of the stoves,
further baffling is necessary to maintain high efficiency. A round baffle with two tabs on each
side is included in the manual bag assembly. To install the round baffle follow these steps:
Tiara I
1. Open the front of the casting.
2. Remove the glass assembly.
3. Remove logs and set aside.
4. Disassemble the square baffle by
unfastening four screws located
inside top of the firebox.
5. Unfasten the two screws on the
existing round baffle, and replace
it with the new round baffle.
Note: The new round baffle is
bigger than the existing round
baffle already on the unit.
6. Re-install the square baffle re-
moved in Step 4.
Figure 8 and table show a straight ver-
tical vent configuration and termina-
tion approved for use on this model.
Tiara II
The Tiara II has an adjustable baffle (see
Figure 7). The baffle setting is dependent
upon the amount of vertical flue. The set-
tings are as follows:
Œ=
All horizontal terminations and verti-
cal runs under 4m.
=
Vertical runs between 4m and 6m.
Ž=
Vertical runs between 7m and 9m.
=
Vertical runs between 10m and 12m.
16
Œ

Ž

Round and Square Baffle
Tiara I
Figure 6.
ADJUST BAFFLE SETTING
Figure 7.
FIREBOX TOP
ROUND BAFFLE
SQUARE BAFFLE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tiara ii-ce

Table of Contents