For round cap
termination:
1. Secure the 168 mm
pipe, using the
exterior pipelock
hole on the round
flange of the wall
firestop.
For trapezoidal
termination:
1. Screw the cap to
the exterior wall
through the
flanges in the cap.
2. Seal the joint
between the pipe
and the exterior
firestop.
WARNING
!
THE TERMINATION CAP MUST BE
POSITIONED SO THAT THE
ARROW IS POINTING UP.
For roundcap termination kits:
Use the exterior pipelock hole provided on the
round flange of the wall firestop to secure the
flue pipe in place.
For trapezoidal cap termination kits:
Using screws, secure the cap to the exterior wall
through the flanges built into the cap.
Use a high-temperature sealant or fiberglass
rope gasket to seal between the 168 mm pipe
and exterior firestop.
ROUND CAP TERMINATION
PERFORATION CANNOT BE
7 1/2"
(191mm)
MINIMUM
TRAPEZOID CAP TERMINATION
Figure 20. Round and Trapezoid Termination
Caps
INSIDE THE WALL
7 1/4"
(184mm)
27