Raymarine AXIOM 2 PRO Installation Instructions Manual page 55

Hide thumbs Also See for AXIOM 2 PRO:
Table of Contents

Advertisement

Important:
• When planning and wiring, take into consideration other products in
your system, some of which (e.g. sonar modules) may place large power
demand peaks on the vessel's electrical system, which may impact the
voltage available to other products during the peaks.
• The information provided below is for guidance only, to help protect
your product. It covers common vessel power arrangements, but does
NOT cover every scenario. If you are unsure how to provide the correct
level of protection, please consult an authorized dealer or a suitably
qualified professional marine electrician.
Implementation — connection to distribution panel (Recommended)
Item
Description
1
Waterproof fuse holder containing a suitably-rated inline fuse
must be fitted. For suitable fuse rating, refer to: Inline fuse and
thermal breaker ratings.
2
Product power cable.
3
Drain wire connection point.
• It is recommended that the supplied power cable is connected to a suitable
breaker or switch on the vessel's distribution panel or factory-fitted power
distribution point.
• The distribution point should be fed from the vessel's primary power
source by 8 AWG (8.36 mm
2
• Ideally, all equipment should be wired to individual suitably-rated thermal
breakers or fuses, with appropriate circuit protection. Where this is
not possible and more than 1 item of equipment shares a breaker, use
Power connections
) cable.
individual inline fuses for each power circuit to provide the necessary
protection.
• The power cable supplied with your product includes a drain wire, which
must be connected to the vessel's common RF ground.
Item
Description
1
Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4
Waterproof fuse holder containing a suitably-rated inline fuse
must be fitted. For suitable fuse rating, refer to: Inline fuse and
thermal breaker ratings.
Important:
Observe the recommended fuse / breaker ratings provided in the product's
documentation, however be aware that the suitable fuse / breaker rating is
dependent on the number of devices being connected.