POWER CORD INSTALLATION
Remove the power cord from inside the vendor. Remove the connection
box cover retaining screw and route the cord under the cover. Keep
power cord secured on the center back of the cabinet until the vendor is
placed into its final location to prevent damage to the cord.
INSTALL BACK SCREEN PROTECTOR
Fasten the Back Screen Protector in place with the screen screws included
with protector. Protector should be placed so the air is forced upward.
(See Figure 7).
FIG 7 . : Back Screen Protector Installation
(airflow up)
LEVEL THE VENDOR
Position the vendor in its place of operation no farther than nine feet from the power outlet or receptacle. Check that the door will open
fully without interference.
Leave at least six (6") inches of space between the back of the vendor and any wall or obstruction for proper air circulation.
All levelers must touch the floor. The vendor must be level for proper operation, cabinet to door alignment, condensate drainage and for
acceptance of coins through the coin mechanism. Adjust the four (4) leg levelers on the cabinet legs first to make the cabinet level front-
to-back and left-to-right. After the cabinet is level adjust the front leg mount levelers to touch the floor surface. The front leg mount
levelers should not support the weight of the cabinet.
GROUNDING (EARTHING) & ELECTRICAL
Consult local, state, and federal codes and regulations before installing the vendor.
Refer to the Safety Installation Guidelines document found in the service package shipped with
your vendor.
Before connecting the vendor, the integrity of the main electrical supply must be checked for
correct polarity, presence of ground (earth) and correct voltage. These checks should be repeated
at six-month intervals with the routine safety electrical testing of the vendor itself.
If the receptacle is not properly grounded or polarized, contact a licensed electrician to correctly polarize and/or ground the receptacle to
ensure safe operation.
For proper operation of any equipment utilizing electronically controlled components, the equipment should be placed on an isolated, or
dedicated, noise-free circuit properly polarized and grounded. Use of a surge suppressor is recommended for locations where electrical
noise is present.
MAIN POWER SWITCH
Main Power
Plug the power cord into a dedicated power outlet. Open the vendor door. Turn on
Switch
the main power switch located on the Power Panel within the cabinet. See Figure
8.
Door Glass
Heater
DOOR GLASS HEATER HARNESS CONNECTION
Connection
The Door Glass Heater Harness Connection is normally disconnected to conserve
energy. In environments where the humidity is above 70% the Glass Heater
Harness should be connected to prevent water condensation from forming on the
glass surface. When the ambient conditions are below 70% humidity the glass
FIG 8. : Power Panel
should be disconnected. See Figure 8.
ADVANCED POWER MANAGEMENT
The Vendor control system is capable of conserving energy by adjusting time periods and temperature for the refrigeration and lighting.
(see programming manual).