3.
In "CC-Link IEF Basic Setting", select "Use" for "To Use or Not to Use CC-Link IEF Basic Settings", and double-click
"Detailed Setting" of "Network Configuration Settings".
4.
Click [Detect Now].
When the MR-JET-G profile is not registered, refer to the following.
Page 59 Downloading and Registering a Profile
5.
The information of the servo amplifiers connected to the programmable controller is displayed in the table. Check the
settings of model name, reserved station, IP address, and subnet mask, and click [Close with Reflecting the Setting].
In this manual, the following setting values are used. (For the setting values, refer to  Page 11 System Configuration.)
If a displayed value is different from the one in the table below, correct the value.
Model Name
STA#
MR-JET-G
1
MR-JET-G
2
Double-click
RSVD STA
IP Address
No Setting
192.168.3.1
No Setting
192.168.3.2
3 PROGRAMMABLE CONTROLLER SETTINGS
Subnet Mask
255.255.255.0
255.255.255.0
26
3.5 Parameter Settings
3