Advertisement

5.
Set as shown below. After the parameters are set, check the connection to the servo amplifiers by clicking
[Communications Test]. When the connection has succeeded, click [OK].
Item
Connection Network
Via
PC side I/F
Servo Amplifier Configuration
*1 For the fourth octet of IP addresses, the values set by the rotary switches in the step 1 are used. Thus, the IP addresses are as shown
below.
 Station number 1: 192.168.3.1
 Station number 2: 192.168.3.2
Precautions
When the communication test detects a connection failure, perform the following.
• Check the power supplies of the programmable controller and the servo amplifiers, wiring with Ethernet cables.
• Check the IP address and the subnet mask of the personal computer.
• Initialize the servo amplifiers.
For how to initialize servo amplifiers, refer to the following.
MR-JET-G User's Manual (Introduction) [4.6 Servo amplifier setting initialization]
2 SERVO AMPLIFIER SETTING
15
2.3 Ethernet Parameter Settings
Protocol
Time-out
Retry
Model
*1
IP address
Setting value
Axis 1
CC-Link IEF Basic
None
UDP
1s
0 times
MR-JET-G
192.168.3.1
Axis 2
MR-JET-G
192.168.3.2