Larius OMEGA 5:1 Manual page 67

Table of Contents

Advertisement

Available languages

Available languages

SAFETY INSTRUCTIONS FOR THE INSTALLATION IN DANGEROUS AREAS
Before installation please read carefully the use and maintenance manual. All maintenance operations must
be carried out as reported in the manual.
The grounding cable of these pumps must be connected by means of suitable electrical connector.
The feeding and suction hoses should be metal pipes, or plastic pipes with metal braid or plastic pipes with textile braid
equipped with a suitable grounding conductor.
Pumps must be installed on containers made of metal or antistatic material,duly grounded.
Gas or vapour rising from flammable liquids shall belong to the group IIB.
The user must periodically control the presence of foulings, the cleaning and wear conditions and the proper operation of
the pump, according to the type and use of the product
The user should periodically clean the suction filter in order to prevent foreign matters entering into the pump. The air used
to supply power to the pump must be filtered and come from a safe area (SAFE AREA).
The pneumatic piston pumps OMEGA series must not run dry.
All of the installation and maintenance operations must be performed by qualified personnel.
we
Larius S.r.l.
Via Stoppani, 21
23801 Calolziocorte (LC)
declare under our sole responsability that the product:
VEGA series pneumatic piston transfer pump.
to which this declaration relates complies with the following directives:
- Directive 94/9/EC
The conformity are under observance of the following standards or
standards documents:
- EN 1127-1
- EN 13463-1
Markings
II 2 G c IIB T6 Tamb.: - 20°C ÷ 60°C Tmax. fluid: 60°C
X
:
Tech. File:
OMEGA/ATX/08
Technical dossier kept on file c/o: INERIS (0080)
Calolziocorte- LC, 15/12/2008
ED. 01 - 09/2022 - Cod. 150206
(ATEX)
- EN 13463-5
Signature (LARIUS)
OMEGA 5:1
IT EN
www.larius.com
67

Advertisement

Chapters

Table of Contents
loading

Table of Contents