Insert the springs (55) and the valves (56) into the seat
(54). Position the seat on the pump support and lay the
manifold (57) on the seat [do not forget the gasket (58)].
Fasten the manifold with screws (do not tighten) ensuring it
is perfectly parallel to the other manifold and the distance
between them is 46 mm (see illustration).
The distance between the walls of the manifold and the
edge of the seat must be about 0,8 mm
0,8 mm
Fig. 9N
Rub the rollers (59) and the pins (60) with vaseline grease
and insert them into the mount (61).
Rub the rubber pad (62) and the washer (63) with vaseline
grease and insert them into the mount (61).
Grease the roller pushing pistons (64), the spring guide
rods (65), the springs (66) and insert them into the mount
(61).
Fasten without tightening the ring nuts (67) on the mount
(61).
Fasten the mount on the manifolds and tighten the screws
(69) [do not forget of washer (68)].
Tighten the ring nuts (67) and the screws (70).
Assemble again the covering and all the fittings of the air
supply line.
ED. 01 - 09/2022 - Cod. 150206
46 mm
0,8 mm
54
61
59
62
63
54
55
57
OMEGA 5:1
56
57
Fig. 10N
www.larius.com
IT EN
58
69
68
67
70
67
66
65
64
60
51