4.6.3

Parameter names

Some of the parameter names are abbreviated in the software because of the limited number
of characters in the display. The full names of the parameters are used in this manual.
The following table shows the full parameter names and the equivalent names used in the
software:
Full parameter name
Profile parameters
Creep distance OPEN
Cutter distance OPEN
Creep distance CLOSE
Cutter distance CLOSE
Maximum speed OPEN
Creep speed OPEN
Cutter speed OPEN
Initial speed OPEN
Maximum speed CLOSE
Creep speed CLOSE
Cutter speed CLOSE
Initial speed CLOSE
Acceleration ramp OPEN
Braking ramp CLOSE
Reversing ramp OPEN/CLOSE
Acceleration ramp CLOSE
Braking ramp CLOSE
Reversing ramp CLOSE/OPEN
Continuous torque (power) OPEN
Continuous torque (power) CLOSE
Cutter press-on torque CLOSE
Static opening force
Static closing force
Static cutter force CLOSE
Reversing distance CLOSE
Special parameters
Hold-open time after OPEN command
Hold-open time after motion detector
Hold-open time after obstruction
Time delay in wait mode CLOSE
Time delay in wait mode OPEN
Number of CLOSE obstructions before wait mode
Number of OPEN obstructions before wait mode
Time limit motion detector
Time delay motion
X11 relay mode
SIDOOR ATD400T door control units for railway applications
System Manual, 06/2020, A5E42201947-AB
4.6 Operating and parameterizing controllers
Parameter name as shown in the software
slow end open distance
slow start open distance
slow start close distance
slow end close distance
maximum speed open
slow end speed open
slow start speed open
slow speed open initial
maximum speed close
slow start speed close
slow end speed close
slow speed close initial
acceler. ramp open
Braking ramp OPEN
reversal ramp op/cl
acceler. ramp close
deceler. ramp close
reversal ramp cl/op
idle torque open
idle torque close
peak torque close
limit force open
limit force close
limit force end close
Reversing distance close
Hold-open time after OPEN command
Hold-open time after motion detector
Hold-open time after obstruction
Time delay in wait mode CLOSE
Time delay in wait mode OPEN
Number of obstructions CLOSE before wait
Number of obstructions OPEN before wait
Time limit motion.
Time delay motion
X11 mode
Controllers
57

Advertisement

Table of Contents
loading

Table of Contents