Requirements
The installation site must fulfill the following requirements:
• Minimum clearance to surrounding parts 1 cm
• Even mounting surface
• Maximum distance from the geared motor on account of the cable length:
– With SIDOOR M3, MDG180 R DIN EN 45545-2: 1.5 m
Measures for complying with temperature class T3:
• Use a sufficiently large (at least 350 x 350 mm), unpainted, metal mounting plate
• The maximum air temperature of 85 °C must not be exceeded in the vicinity of the printed
circuit board
Risk of injury as a result of incorrect installation
Final application-specific requirements must be observed.
SIDOOR ATD400T door control units for railway applications
System Manual, 06/2020, A5E42201947-AB
WARNING
Controllers
4.1 Description of controller