Siemens SIDOOR ATD400T System Manual page 52

Automatic door control
Hide thumbs Also See for SIDOOR ATD400T:
Table of Contents

Advertisement

Procedure
5.
The door parameters and the determined door width are saved when
the door is in the CLOSED position.
This means that the door width, door weight, energy limitation and
speed limitation are re-adapted and saved.
6.
Learn run completed.
Service buttons OPEN and CLOSE
Door movements in the OPEN direction can also be made manually with the service button
S402 (OPEN). The door travels in the OPEN direction as long as the service button S402
(OPEN) is pressed. When the button is no longer pressed, the door travels in the CLOSE
direction.
The service button S403 (CLOSE) has no function.
Note
Operation with the SIDOOR SERVICE TOOL or the SIDOOR USER SOFTWARE
Alternatively, you can control the doors with the SIDOOR SERVICE TOOL or the SIDOOR USER
SOFTWARE. In this case, the external input signals are disabled in some menus. Additional
information is available in the section SIDOOR SERVICE TOOL (Page 80) and in the SIDOOR
SOFTWARE KIT Operating Instructions
(http://support.automation.siemens.com/WW/view/en/92711247).
SIDOOR ATD400T door control units for railway applications
System Manual, 06/2020, A5E42201947-AB
4.6 Operating and parameterizing controllers
H401 display
H1 display
Controllers
51