Static closing force
This force is effective during the closing movement if a close command is present.
Figure 4-6
Current – force – motor characteristic in closing direction
Adjustment ranges
The value of the parameter must be selected so that the door moves across the entire door
width in the closing direction if a close command is present. Inadequate force can lead to an
obstruction of the door.
The closing force can be set for the geared motors within the adjustment ranges of the
parameters (see Section Profiles and adjustment ranges (Page 100)).
SIDOOR ATD400T door control units for railway applications
System Manual, 06/2020, A5E42201947-AB
4.6 Operating and parameterizing controllers
Controllers
61