Fan Motor; Basic Parameters; Checking Method; Removing The Fridge Electric Wind Gate - Hisense BCD-543WPAZR/HC1(E) Service Manual

Table of Contents

Advertisement

6.4 Fan motor

6.4.1 Basic parameters

Rated voltage:
F.FAN: DC12V
C.FAN: DC12V

6.4.2 Checking method

1. Check the connecting wiring of fan motor is well or not, repair if it's broken.
The freezer fan motor corresponding pin No. 13~15 on CN4 connector of main-board, as
the drawing below.
The condenser fan motor corresponding pin No. 1~2 on CN4 connector of main-board, as
the drawing below.
2. Pin No. 14connect 12V power and pin No. 13connect GND, if the freezer fan motor
works normally, change the main-board; If not , change the freezer fan motor.
Pin No. 2 connect 12V power and pin No. 1 connect GND, if The condenser fan motor
works normally, change the main-board; If not , change the condenser fan motor.

6.4.3 Removing the fridge electric wind gate

Step 1: Remove two screws (1) holding the fridge air return cover with a Philips
screwdriver.
Step 2: Remove two screws (2) holding the fridge air duct with a Philips screwdriver.
Step 3: Remove two wire connectors (3) and (4) by pressing the top of them.
Step 4: Remove the fridge air duct (5) with your both hands.
42 / 56

Advertisement

Table of Contents
loading

Table of Contents