IDEAL FP14KC-X Installation & Operation Manual page 18

Four post closed front commercial vehicle lift 14,000 lb. capacity
Table of Contents

Advertisement

CAUTION! Locking Latches require compressed air pressure of 90 PSI Min to 115 PSI Max for
proper latch operation.
NOTE: To assemble airline tubing into push fittings, use firm pressure to push tubing into
fitting until it bottoms out. Ensure tubing is cut square with no burrs, Fig 28.
7) Route and connect D6 Airlines to Lift for Latch operation, Fig. 27. Cut D6 airline to connect Air Fitting
to Air Valve. Connect airline from Air Fitting to Air Valve using 'Inlet' Valve Port 'A', Figs. 27 A & B.
Air Cylinder
(Route Airline thru Hole in
8) Connect D6 Airline to the 'Outlet' Valve Port 'P' and route through Flex Tubing to connect to T Fitting.
Connect airlines to each end of T-Fitting, then connect to Y Fittings in Crossbeams, Figs. 27, 27-A &-B.
'Inlet'
D6 Airline to
Air Valve
Air Valve
'Quick
Disconnect'
Air Fitting
'Outlet'
D6 Airline to
T Fitting
Fig. 27-A
Y Fitting
Crossbeam to Y Fitting)
LH Power Side Runway
Crossbeam
(See Details) Figs. 27 A & B
Air Valve
Airline (D6)
Runway Airline (D6)
(Route thru Metal Rings)
Fig. 27
Air Valve
(Push Button)
'Inlet'
Port
'Outlet'
Port
Fig. 27-B
18
FP14KC-X
JAN 2023
Runway
T Fitting
Airline (D6)
Air Cylinder
Airline
'Push'
Fitting
D6
Airline
Push
Sleeve
Fig. 28
Y Fitting

Advertisement

Table of Contents
loading

Table of Contents