Technical specifications
Article number
Diagnostics indication LED
•
•
•
•
•
•
•
•
•
•
Potential separation
between the load voltages
between Ethernet and electronics
Potential separation channels
•
•
Isolation
tested with
•
•
Degree and class of protection
IP degree of protection
Standards, approvals, certificates
Suitable for safety-related tripping of standard
modules
Highest safety class achievable for safety-
related tripping of standard modules
•
•
•
Ambient conditions
Ambient temperature during operation
•
•
Altitude during operation relating to sea level
•
56
RUN LED
ERROR LED
MAINT LED
NS LED
MS LED
IO LED
Channel status display
for channel diagnostics
For load voltage monitoring
Connection display LINK TX/RX
between the channels
between the channels and the power supply
of the electronics
24 V DC circuits
Test voltage for interface, rms value [Vrms]
Performance level according to ISO 13849-1
Category according to ISO 13849-1
SILCL according to IEC 62061
min.
max.
Ambient air temperature-barometric pressure-
altitude
6ES7142-6BR00-0BB0
Yes; green LED
Yes; red LED
Yes; Yellow LED
Yes; green/red LED
Yes; green/red LED
Yes; red-green-yellow LED
Yes; green LED
Yes; red LED
Yes; green LED
Yes; green LED, only link
Yes
Yes
No
Yes
707 V DC (type test)
1 500 V; According to IEEE 802.3
IP65/67
Yes; From FS02
PL d
Cat. 3
SILCL 2
-40 °C
60 °C
Up to max. 5 000 m, at installation height > 2 000
m additional restrictions
I/O device digital outputs DQ 8x24VDC/2A M12-L 8xM12 (6ES7142-6BR00-0BB0)