Terse
Verbose
64
CONNECT 28800 Connected at 28800 bps and line speed reporting enabled. Modem connects to the line;
66
+DR: ALT
67
+DR: V.42B
69
+DR: NONE
70
+ER: NONE
77
+ER: LAPM
78
+MRR: 31200
79
+MRR: 33600
80
+ER: ALT
83
LINE-IN-USE
84
CONNECT 33600 Connected at 33600 bps. Modem connects to the line, the DTE speed is 33600 bps and
91
CONNECT 31200 Connected at 31200 bps. Modem connects to the line DTE speed of 31200 bps and the
134
+MCR: B103
135
+MCR: B212
136
+MCR: V21
137
+MCR: V22
138
+MCR: V22B
139
+MCR: V23
140
+MCR: V32
141
+MCR: V32B
142
+MCR: V34
145
+MCR: V90
150
+MRR: 32000
151
+MRR: 34000
152
+MRR: 36000
153
+MRR: 38000
154
+MRR: 40000
155
+MRR: 42000
156
+MRR: 44000
157
+MRR: 46000
158
+MRR: 48000
159
+MRR: 50000
Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273F)
Description
either the line speed is 28800 bps and DCE speed reporting is enabled, or the DTE
speed is 28800 bps and DTE speed reporting is enabled.
Connected in MNP Class 5 data compression. Modem connects to the line in MNP
Class 5 and +DR: message reporting is enabled. (See S95, Wn, Xn.)
Connected in V.42 bis data compression. Modem connects to the line in V.42 bis and
120 +DR: message reporting is enabled. (See S95, Wn, Xn.)
Connected without data compression. Modem connects to the line without data
compression and +DR: message reporting is enabled. (See S95, Wn, Xn.)
Connected without any protocol. Modem connects to the line without any form of error
correction and +ER: message reporting is enabled. (See S95, Wn, Xn.)
Connected in V.42 LAPM mode. Modem connects to the line in V.42 LAPM error
correction mode. +ER: message reporting is enabled. (See S95, Wn, Xn.)
Connected at 31200 bps; carrier reporting enabled. Modem connects to the line
at31200 bps and carrier reporting is enabled. (See S95, Xn.)
Connected at 33600 bps; carrier reporting enabled. Modem connects to the line
at33600 bps and carrier reporting is enabled. (See S95, Xn.)
Connected in MNP mode. Sent when the modem connects in MNP mode of error
correction. +ER: message reporting has been enabled. (See S95, Wn, Xn.)
Line in use. Modem attempted to go off-hook when an extension was already occupying
the line.
the DTE speed reporting is enabled.
modem is to report the DTE speed upon connecting.
Connected with Bell 103 modulation. Modem connects to the line with Bell 103
modulation and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with Bell 212 modulation. Modem connects to the line with Bell 212
modulation and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.21. Modem connects to the line with ITU-T V.21 modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.22. Modem connects to the line with ITU-T V.22 modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.22B. Modem connects to the line with ITU-T V.22B modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.23. Modem connects to the line with ITU-T V.23 modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.32. Modem connects to the line with ITU-T V.32 modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.32B. Modem connects to the line with ITU-T V.32B modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.34. Modem connects to the line with ITU-T V.34 modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected with ITU-T V.90. Modem connects to the line with ITU-T V.90 modulation
and modulation reporting is enabled. (See +MR, S95, Xn.)
Connected at 32000 bps. Modem connects to the line at 32000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 34000 bps. Modem connects to the line at 34000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 36000 bps. Modem connects to the line at 36000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 38000 bps. Modem connects to the line at 38000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 40000 bps. Modem connects to the line at 40000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 42000 bps. Modem connects to the line at 42000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 44000 bps. Modem connects to the line at 44000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 46000 bps. Modem connects to the line at 46000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 48000 bps. Modem connects to the line at 48000 bps and carrier
reporting is enabled. (See S95, Xn.)
Connected at 50000 bps. Modem connects to the line at 50000 bps and carrier
reporting is enabled. (See S95, Xn.)
Chapter 7 – Result Codes