Page 2
Maintenance
4 5
S erie CAUTION Before resetting your electronic card that displays an error code. Error Code H Service the stove COMPLETELY as described in this • manual. Check the chimney pipe. • Error Code O Service the stove COMPLETELY as described in this •...
Page 3
Maintenance
4 5
S erie MINIMUM RECOMMANDED MAINTENANCE SCHEDULE Weekly Monthly Annually Components Daily Or after Or after +/- 10 bags +/- 25 bags Per ton of pellets Burn Pot Empty Empty and Brush Glass Wipe Clean Activate the cleaning Heat Exchanger Activate the cleaning rod...
Maintenance
4 5
S erie REMOVE THE BAFFLE. 1. Lift the baffle and slide forward it a little to clear the supports. 2. Lower the baffle until the tab is behind the burn pot receptacle. 3. Rotate the baffle and align the right corner to the upper right corner of the door opening.
Page 5
Maintenance
4 5
S erie CLEAN THE HEAT EXCHANGER TUBES. cleaning rods must activated as often as possible. #1 Pull and push the rod 4-5 times. #2These rods activate a rake that cleans the heat exchanger tubes. Note: The stove will produce more heat if the heat exchanger tubes are clean.
Page 6
Maintenance
4 5
S erie CLEAN THE EXHAUST DUCTS To access the exhaust ducts, remove the wall on the left side of the burning pot. 1. Remove 3 screws on the right and 2 screws left side of the panel. 2.
Page 7
Maintenance
4 5
S erie CLEAN THE EXHAUST DUCTS It is difficult to insert the vacuum hose into the NEXT. openings. Using a ¾ inch hose installed on a vacuum adapter will facilitate access to these tight spaces. The cleaning of the exhaust ducts is made of 3 important openings.
Page 8
Maintenance
4 5
S erie CLEAN THE BURN POT. Using a scraper and a wire brush, thoroughly clean the surface of the burn pot. It is very important to leave no residue on the surface of the burn pot. Note: The sand and dirt contained in the wood pellets does not burn and solidifies to form a stone on the surface...
Page 9
Maintenance
4 5
S erie CLEAN THE BURN POT RECEPTACLE After removing the burn pot vacuum the ash within the burn pot receptacle. THE ASH DUMP CAP MUST BE IN Vacuum the ash at the bottom of the PLACE.
Page 10
Maintenance
4 5
S erie CLEANING THE EXHAUST FAN The Access to the exhaust fan is on the left side of the pedestal. Follow these steps remove the left panel of the pedestal. 1. Unscrew the 2 retaining screws located behind...
Page 11
Maintenance
4 5
S erie CLEANING THE EXHAUST FAN NEXT Remove the plate from the exhaust fan by unbolting the 4 bolts. Vacuum the ash and clean the fins of the fan using a small brush. ...
Page 12
Maintenance
4 5
S erie CLEANING THE PRESSURE SWITCH TUBE. The pressure sensor is attached to the back grill of the stove to access the sensor open the left side panel of the stove. Remove the tube from the pressure sensor.
Page 13
Maintenance
4 5
S erie THIS PELLET STOVE IS EQUIPED WITH MULTIPLE DEVICES TO ENSURE YOUR SAFETY. HOWEVER IF A WARNING ERROR CODE STOPS YOUR STOVE ON SEVERAL OCCASIONS, IT IS VERY LIKELY TO BE THAT THE STOVE DOES NOT EXAUSHT PROPELY. YOU HAVE THE RESPONSIBILITY TO MAKE SURE THAT THE MAINTENANCE OF THE STOVE IS DONE AS DESCRIBED IN THIS DOCUMENT.
Page 14
Maintenance
4 5
S erie TO RESET CODE O To reset the error code 0 in 3 steps. Error Code O 1. Unplug the stove 2. Reset the L250 manual. (See the photo on the left) 3. Press the button “RESET”...