If your data device is a synchronous device, then click the Synchronous option and the Sync
Parameters are displayed. Ensure that the clocking and, if an internal clock is used, the Speed is
correct. Also, check the Encoding Scheme, Between Frames, and InterFrame Timer are correct
for your data device. Refer to user documentation for the parameters of the data device.
When you have completed your data port configurations, click OK.
12. The Frame Relay DLCI Default Setup dialog box is displayed.
Your MultiFRAD can detect the DLCI and the frame relay management type when the unit is
connected to an active frame relay network service. At this point your MultiFRAD is not
communicating with the frame relay network. But if you know your DLCI and want to add it at this
point, you can continue with the next step. If you wish to wait until your MultiFRAD is
communicating with the frame relay network, proceed to step 13 to finish installing your software.
• Click on the DLCI number field to change the default DLCI to the number provided by your
service provider at subscription time.
• Click on the Committed Information Rate numeric box in the Settings (in Bits/second) category
and enter the CIR value provided by your service provider at subscription time for this DLCI.
• Click on the Excess Burst Rate (Be) numeric box in the Settings (in Bits/second) category and
enter the Be value provided by your service provider at subscription time for this DLCI.