Commissioning
ε
Media
DC (
r)
group
1
1.4...1.6
– Plastic granulate
– White lime, special cement
2
1.6...1.9
– Sugar
– Portland cement, plaster
3
1.9...2.5
– Flour
– Grain, seeds
4
2.5...4
– Ground stones
– Sand
– Naturally moist (ground)
5
4...7
– Sal
– Metallic powder
6
> 7
– Carbon black
– Coa
The lower group applies to very loose or loosened bulk solids. Reduction of the max. possible
measuring range by means of:
• extremely loose surfaces of bulk solids, e.g. bulk solids with low piled density when filled
pneumatically.
• Build-up, primarily of moist products.
!
Note!
Due to the high diffusion rate of ammonia it is recommended to use the FMP45 with gas-tight
bushing for measurements in this medium.
28
Typical bulk solids
stones, ores
Typical liquids
– Condensed gases, e.g. N
CO
2
– Liquefied gas, e.g. Propane
– Solvent
– Frigen / Freon
– Palm oi
– Mineral oils, fuels
—
⎯
– Benzene, styrene, toluene
– Furan
– Naphthalene
– Chlorobenzene,
chloroform
– Cellulose spray
– Isocyanate, aniline
– Aqueous solutions
– Alcohols
– Ammonia
Levelflex M FMP41C 4...20 mA HART
Measuring range
bare metallic
PA-coated rope
probes
,
4m / 157", only
2
coax probe
25...30m /
984...1181"
30...35m /
1181...1378"
—
⎯
35m / 1378"
35m / 1378"
35m / 1378"
Endress+Hauser
probes
—
12,5...15m /
492...590"
—
15...25m /
590...984"
25...30 m /
984...1181"
25...30m /
984...1181"
35m / 1378"
35m / 1378"
Need help?
Do you have a question about the HART Levelflex M FMP41C and is the answer not in the manual?
Questions and answers