Page 2
100V 13-247-22Q Medium 230V 13-247-30Q Dual 120V 13-247-31Q Dual 100V MANUAL NUMBER 103751 (7000621) 40460 9/9/15 Removed CE references 31325 2/13/15 Added explosion and fire cautions 5/13/10 Transfer to Marietta (was 103751 10/4/06) ECR/ECN DATE DESCRIPTION Fisher Scientific Hybridization Incubators...
Page 3
Fisher Scientific makes no representations or warranties with respect to this manual. In no event shall Fisher Scientific be held liable for any damages, direct or incidental, arising out of or related to the use of this manual.
Page 4
EU Member State European Country, and this product should be disposed of or recycled through them. Further information on Fisher Scientific’s compliance with this directive, the recyclers in your country and information on these products will be available at www.fishersci.com.
Page 5
When more extensive service is necessary, we will assist you with direct factory trained technicians or a qualified service organization for on-the-spot repair. If your service need is covered by the Fisher Scientific Products warranty, we will arrange for the unit to be repaired at our expense and to your satisfaction.
Introduction Section 1 This manual provides information and procedures on how to unpack, set up, and operate the Fisher Scientific Isotemp brand of Hybridization Incubators. This manual is intended to be used by Fisher customers responsible for operating the hybridization incubator.
The dual unit, accepts two rotisseries, identical to those describe for use in the medium unit. As an alternative to rotisseries, a rocker is available for agitating samples. The rocker is an option on the medium and dual units and it replaces the rotisserie. Hybridization Incubators Fisher Scientific...
(see above). Note The red bar to the left of the display indicates a negative value. Used in calibrating the unit. Indicates that the unit is operating in the alarm condition ALARM Alarm (the indication is only seen during the alarm condition). Fisher Scientific Hybridization Incubators...
Page 13
• Do not continue to use the incubator if the temperature controller fails, as evidenced by the red ALARM indicator lighting. • Use appropriate hand and eye protection when handling hazardous chemicals. Hybridization Incubators Fisher Scientific...
Page 14
Tilt incubator to allow grasping under bottom of unit at the sides or back. Do not lift by grasping under plastic bezel at front of unit. Dual unit may require a third person to prevent unit from tipping while being moved. Fisher Scientific Hybridization Incubators...
5. Install drip tray inside incubator Wall bracket chamber. Wall 6. Plug the power cord into a suitable grounded electrical outlet. 7. Check out system operation before using unit. 8. Complete and return warranty Figure 4-1. Wall Bracket card. Hybridization Incubators Fisher Scientific...
Shows messages to indicate Use in conjunction with menu menu functions. key to access other functions. Take action depending on Shows status and error mes- message. (See Power Up sages. Messages) Fisher Scientific Hybridization Incubators...
Plug mating end of power power entry module/ power to unit. Filters incoming and cord into this connector. Plug line filter/fuse holder outgoing power line noise. Holds fuses other end into suitable power for over-current protection. outlet. Hybridization Incubators Fisher Scientific...
1. Set the power switch to the I position. Display alternates between oFF and the measured temperature. If you get any other message, see “Power Up Messages” below. 2. Press any key to stop the oFF display. The system displays the actual temperature inside the incubator. Fisher Scientific Hybridization Incubators...
0.0 and 85.0°C. 3. Release the arrow keys when the temperature is set as desired. After ten seconds, the display shows the actual temperature. To return to the actual temperature immediately, press the menu key. Hybridization Incubators Fisher Scientific...
3. Press and hold either the up or down arrow key to set the desired offset. In the example above, you would set the offset to -3.0°C. 4. Check the temperature accuracy again and change the offset as necessary to achieve the desired temperature. Fisher Scientific Hybridization Incubators...
Display shows temperature deviation of 0.0. After ten seconds, the display returns to the actual temperature. To return to the actual temperature immediately, press the menu key. Hybridization Incubators Fisher Scientific...
4. Line up the right side of the shaft with the gear drive socket, as shown in Figure 5-4. Release the rotisserie and allow the shaft to be pushed into the socket. Figure 5-4. Drive Socket Fisher Scientific Hybridization Incubators...
7. Close the incubator door, set the temperature, and set the rotisserie motor switch on to start processing. 8. At the conclusion of processing, set the power switch off, open the incubator door, and unload the rotisserie. Hybridization Incubators Fisher Scientific...
4. Tighten the screws so the rotisserie does not twist. 5. Install the rotisserie into the incubator. Figure 5-5. Screw Locations screws screws screws Figure 5-6. Small Incubator Screw Locations Fisher Scientific Hybridization Incubators...
3. Place the rocker in the incubator and secure it to the back of the incubator with the two existing screws from the back panel, as Figure 5-7. Rocker Installation shown in Figure 5-7. 5-10 Hybridization Incubators Fisher Scientific...
2. Use the rotisserie motor switch to jog the rocker if necessary to assist in removing samples. 3. Set the power switch off. 4. Clean the unit in preparation for the next use. Fisher Scientific Hybridization Incubators 5-11...
Where there is a heavy coating of residue on the stainless surfaces, or where there is evidence that corrosion is beginning, use a stainless steel cleaner. • Rinse and wipe all surfaces with clean water and allow to air dry. Fisher Scientific Hybridization Incubators...
Display alternates between actual Temperature setting has been reduced below current temperature and Alr (alarm). chamber temperature. Defective solid-state relay. Defective thermocouple; defective temperature con- ALARM light on troller board; defective solid state relay, defective safety thermostat. Fisher Scientific Hybridization Incubators...
SPN40521 Power cord, Euro SPN83115 Power cord, UK SPN83117 Door gasket SPN103967 Front panel overlay, with “wave” SPN103974 Front panel overlay, no “wave” SPN103975 Rotisserie tube clip, 35 mm SPN103958 Rotisserie tube clip, 70 m SPN104008 Hybridization Incubators Fisher Scientific...
4. Using a 11/32 nut driver, loosen the two nuts that hold motor bracket to the chassis. 5. Slide the motor to the rear to tighten belt tension, then tighten nuts. 6. Replace chassis bottom. Fisher Scientific Hybridization Incubators...
Page 35
4. Using a 11/32 nut driver, loosen the two nuts that hold motor bracket to the chassis. 5. Slide the motor to the rear to tighten belt tension, then tighten nuts. 6. Replace chassis back cover. Hybridization Incubators Fisher Scientific...
(available in pack of 2 or case of 6) Hybridization tube cap O-ring 13-247-RNG Rotisserie, 35 mm, 4/8 tubes 13-247-15 Rotisserie, 70 mm, 2 tubes 13-247-16 Rotisserie, 35 mm, 10/20 tubes 13-247-25 Rotisserie, 70 mm, 4 tubes 13-247-26 Fisher Scientific Hybridization Incubators...