Technical Configuration (Analog/BRI)
DID Interface Parameter Definitions (cont'd)
Field Name
DID Options (cont'd)
Start Modes
Wink Timer
(in ms)
Dialing Options
Inter Digit
Timer
Message
Waiting
Indication
Inter-Digit
Regeneration
Timer
Values
Description
Immediate Start,
For Wink Start, the voip detects
Wink Start,
the off-hook condition. Then
Delay Dial
the voip reverses battery
polarity for a specified time
(140-290 ms; a "wink") and then
becomes ready to receive dial
digits.
For Delay Dial, the voip detects
detects the off-hook condition.
Then the voip reverses battery
polarity for a specified time
(reverse polarity duration has
wider acceptable range than for
Wink Start) and then becomes
ready to receive dial digits.
integer values,
This is the length of the wink
in milliseconds
for Wink Start and Delay Dial
signaling modes..
Applicable only when Start
Mode parameter is set to "Wink
Start" or "Delay Dial."
integer values,
This is the length of time that
in seconds
the MultiVOIP will wait
between digits. When the time
expires, the MultiVOIP will
look in the phonebook for the
number entered.
Default = 2.
--
Not applicable to DID-DPO
interface.
integer values,
This parameter is applicable
in milliseconds
when digits are dialed onto a
DID-DPO channel after the
connection has been made. The
length of time between the
outputting of DTMF digits.
Default = 100 ms.
260
MultiVOIP User Guide
Need help?