Before You Use The Product - EcoFlow Smart Generator Dual Fuel User Manual

Hide thumbs Also See for Smart Generator Dual Fuel:
Table of Contents

Advertisement

2.3 Before You Use the Product

Adding fuel (when using gasoline)
Danger
Please read the Safety Guidelines carefully before refueling as
fuel is inflammable and toxic. Do not overfill the fuel tank, as
fuel may expand and spill out when the fuel tank warms up.
Be sure to tightly close the fuel cap after refueling.
Caution
Clean away the residual fuel with a clean and soft cloth after
refueling to avoid damage to the rubber shell. Please use
unleaded fuel rather than leaded fuel which may severely
damage the internal parts of generator. Take off the fuel cap
and fill up until the red indicator.
Recommended fuel: unleaded gasoline
Fuel tank capacity: 1.05 gal. / 4.00 L
Connecting LPG (when using LPG)
1. Make sure the LPG cylinder valve is in the closed position.
2. If you are using a new LPG cylinder, first remove the plastic
cap located on top of the cylinder valve.
3. Connect the LPG hose to the LPG cylinder valve and tighten.
4. Remove the dust cover from the LPG access port of the
generator.
5. Remove the protective rubber plug from the female connector
of the LPG hose.
6. Insert the female connector of the LPG hose into the LPG access
port and push it until you hear a clicking noise, and move the
outer ring of the female connector forward.
Tips: 1. Immediately close the LPG cylinder valve when the generator is shut down.
2. Do not place the LPG cylinder on the side with the generator's muffler.
6
Open fuel cap
Red Indicator
Fuel Filter
Strainer
Refueling
Insert the LPG Hose