The safety of you and others, as well as of property are of the primary importance. Please carefully read the extremely important safety warnings we have written in the User Manual and the sticker of the generator set. This is to remind you of the potential dangers which may harm you and others. Before each safety warning is a symbol and one of the three following words: danger, warning or caution.
These words indicate:
If you fail to follow the instructions, your life will be at risk or you will be severely injured.
If you fail to follow the instructions, your life may be at risk or you may be seriously injured.
If you fail to follow the instructions, your generator set and other property may be damaged.
Please read the User Manual carefully before using the generator in order to avoid accidents.
Do not use indoors and keep away from doors, windows and vents
Do not use in damp environments
Make sure that no fuel is spilled when refueling
Keep any combustibles at least 1m / 3ft away
Do not smoke when refueling
Switch off the engine before refueling
Earthing the Generator
The generator is equipped with system grounding, which is used to connect the generator's frame components to the ground terminal in the AC outlet. The system grounding doesn't connect to the AC neutral.
Connect the Generator to the Electrical System
Do not connect the generator to the electrical system of a building, unless an isolation switch has been properly installed by a licensed electrician. Please comply with all applicable laws and electrical regulatory requirements.
Keep the air inlets in the side of front panel, the muffler and the bottom of generator clean and unblocked and prevent any debris, mud or water from entering. The generator, the controller or the engine may be damaged if these air inlets become blocked. Do not transport, store or use the generator together with other products. Any oil leaks may damage the generator or endanger your personal safety as well as your property.
Please refer the following stickers carefully before starting to use the product.
Carbon Monoxide Alert Light: When the carbon monoxide sensor detects that the concentration of carbon monoxide is about to exceed the standard, the generator will automatically stop and the carbon monoxide alert light will flash for 5 minutes. During this course, the generator cannot be started. LPG: liquefied petroleum gas.
Remaining Oil Percentage: If the amount of oil falls below 600 ml while the gasoline is in use, the remaining oil percentage will show as 0%. During this time, the icon will flicker to remind you to add more fuel immediately. The display will show 99% when the LPG is in use.
Wi-Fi Status: The devices that support Bluetooth connection will be connected to the App directly or to the Internet after the the network connection process is completed. If it is successfully connected to the Internet, the icon will stay on.
Error Code: Please refer to the EcoFlow app for specific information on error codes.
ECO Mode: In this mode, the generator will automatically match the rpm according to power output level in order to reduce fuel consumption and noise. Default ECO Mode.
ECO Mode Settings:
Adding fuel (when using gasoline)
Please read the Safety Guidelines carefully before refueling as fuel is inflammable and toxic. Do not overfill the fuel tank, as fuel may expand and spill out when the fuel tank warms up. Be sure to tightly close the fuel cap after refueling.
Clean away the residual fuel with a clean and soft cloth after refueling to avoid damage to the rubber shell. Please use unleaded fuel rather than leaded fuel which may severely damage the internal parts of generator. Take off the fuel cap and fill up until the red indicator.
Recommended fuel: unleaded gasoline
Fuel tank capacity: 1.05 gal. / 4.00 L
Connecting LPG (when using LPG)
Tips:
When the engine is running, do not place the LPG hose or the LPG cylinder in the exhaust passage of the muffler.
Add Generator Engine Oil
There is no engine oil in the generator when delivered from the factory. Do not start up the generator until after adding sufficient engine oil. Do not tilt the generator when adding engine oil, to prevent damage to the generator due to adding excessive oil.
Recommended engine oil: SAE SJ 10W-40
Grade of recommended engine oil: API Grade SJ or higher
Oil capacity: 0.1 gal. / 0.38 L
Rechargeable Battery Connection
The generator cannot be started by the Electric Start switch unless connected to the internal battery. Turn the maintain cover knob to , take off the maintenance cover and connect the positive and the negative wires of the battery respectively.
Checking Before Use
Please check the following components carefully each time before using the generator.
Malfunctions While Running
Check for any issues while the generator is running and consult EcoFlow for further technical support if necessary.
Tips: Ambient Temperature for Generator -15℃-40℃ in the gasoline mode, and -5℃-40℃ in the LPG mode. The generators can operate under standard atmospheric conditions ("standard atmospheric conditions"- ambient temperate of 25℃ - atmospheric pressure of 100 kPa - relative humidity of 30%). When the temperature, humidity, and height surpass standard atmospheric conditions, the output of the generator will decrease Using under high temperature for an extended period of time will affect the life cycle of the generator and its built-in battery. Also, the output must be lowered when it is used in small spaces, since it will affect the cooling of the generator.
For fuel selection, the generator will use LPG when the LPG hose is connected and gasoline when the hose is not connected.
The generator can be started using any of the four methods below:
gasoline
To turn the engine off in an emergency, turn the engine switch to the "OFF" position. In any other circumstances, please follow the below steps.
LPG
Switch off all electrical equipment before inserting plugs.
Make sure that all electrical equipment including wires and plugs are in good condition before being connected to the generator, and confirm that all loads carried by the generator are within the rated load range and that the load current is within the rated current range.
Tips: Make sure that the generator is grounded. If any electrical equipment needs to be grounded, the generator must also be grounded.
Tips: When it is automatically started, the generator AC output switch is off by default. When the AC is on, the generator will not be available once the DC is finished. The upper and lower power limits can be set in the app of the portable power station being connected. When charging DELTA Max, DELTA Pro, or Power Kits, it is recommended that the upper power limit be set to 80% in order to increase fuel efficiency. Turn on the AC output switch for simultaneous AC output when the DC output is already on. The total power of AC+DC is 1,800W (gasoline)/1,600 W (LPG), with AC output prioritized.
*When connected the DELTA Pro for charging, you will need to purchase the DELTA Pro to Smart Generator Adapter from the e-commerce store for connecting the generator to DELTA Pro or Power Kits.
* When connected the DELTA Pro Extra Battery for charging, you will need to purchase the DELTA Pro to Smart Generator Adapter from the e-commerce store for connecting the generator to the DELTA Pro Extra Battery.
You can control and view the information and data of the product through the EcoFlow app.
Download at: https://download.ecoflow.com/app
EcoFlow app
Privacy Policy
By using EcoFlow Products, Applications and Services, you consent to the EcoFlow Term of Use and Privacy Policy, which you can access via the "About" section of the "User" page on the EcoFlow App or on the official EcoFlow website at https://www.ecoflow.com/policy/terms-of-use and https://www.ecoflow.com/policy/privacy-policy
Please make sure that the total load of the generator is within the rated range before using the generator, or otherwise the generator may be damaged.
Application | ![]() | ![]() | ![]() |
Power Factor | 1 | 0.8–0.95 | 0.4–0.75 (Efficiency 0.85) |
Output | ≤1,800 W (Gasoline) ≤1,600 W (LPG) | ≤1,440 W (Gasoline) ≤1,280 W (LPG) | ≤612 W (Gasoline) ≤544 W (LPG) |
When this generator is supplying power to precision instruments, electronic controllers, personal computers and microcomputers, please keep the generator a sufficient distance away from any of the foregoing equipment to avoid electromagnetic interference, and at the same time, to ensure that the generator will not be interfered with by these electronic devices. If this generator is used to supply power to medical devices, it is recommended to consult with the corresponding equipment manufacturers and technicians first. This is because some electronic equipment or general purpose machines in hospitals require a strong current upon startup and may not be able to use the generator. Please contact the equipment manufacturer for confirmation even if the respective start parameters of the equipment satisfy the conditions listed in the table above.
Proper maintenance and servicing is essential to ensure safe, economical and reliable usage. This also helps minimize your environmental impact. You must regularly check and service your generator to keep it in optimal condition based on the schedule below.
Item/Servicing Intervals | Each Time | Within the first month or after 20 hours of operation | Once every three months or every 50 hours of operation thereafter | Then once every year or every 100 hours of operation | |
Generator Engine Oil | Check – Add | ![]() | |||
Replace | ![]() | ![]() | |||
Air Filter Element | Check – Add | ![]() | |||
Clean | ![]() | ||||
Replace | ![]() | ||||
Sediment Bowl | Clean | ![]() | |||
Spark Plug* | Clean – Adjust | ![]() | |||
Spark Plug Arrester | Clean | ![]() | |||
Idle Speed ** | Check - Adjust | ![]() | |||
Valve Clearance ** | Check - Adjust | ![]() | |||
Fuel Tank and Fuel Filter ** | Clean | ![]() | |||
Fuel Pipe** | Check | Every 2 years (or replace it if necessary) | |||
LPG Hose** | Check | Every 2 years (or replace it if necessary) | |||
Cylinder Head, Piston | Remove any carbon deposits ** | Every 300 hours | |||
* These items should be replaced if necessary | |||||
** These items should be serviced by their respective dealers unless the user has the appropriate tools and maintenance capacity |
Turn off the generator before starting any maintenance. Place the generator on a level spot and separate the spark plug cap from the spark plug to prevent the generator from starting up. Do not use the generator such in poorly ventilated places such as rooms, rail tunnels or caves. Be sure to keep the working area well ventilated. Exhaust gas from the generator contains toxic carbon monoxide fumes. Inhaling these fumes may lead to shock, loss of consciousness or even death.
The spark plug is an important part of the generator and must be checked regularly.
The carburetor is an important part of engine, and should be adjusted by the dealer who has the professional knowledge, data and equipment to ensure it is adjusted correctly.
Do not drain the engine oil immediately after the generator is switched off. The oil temperature will be very high. Please take care not to get scalded when draining the oil.
Do not twist the foam filter element, to prevent any damage to it.
Never use fuel in any place near smoke or flames.
Be sure to tighten the fuel cap.
Once the generator starts running, the engine and the muffler will become scalding hot. Do not let your skin or clothes directly touch the engine or muffler during your checks and maintenance.
If you plan to place this generator into long-term storage, you need to take some storage measures to prevent premature aging of the generator.
As fuel is highly volatile and toxic, please carefully read the "Safety Guidelines" for handling instructions.
Wipe any spilled fuel away with a clean soft cloth to prevent it from damaging the plastic shell.
Take the following steps to protect parts such as the engine body and piston rings which are the most susceptible to corrosion.
Disconnect the battery each time you store it for a longer period of time and reconnect it before using it again.
Attention: The battery should be charged and discharged once every 3 months. It will charge while the engine is running.
If the generator is stored with fuel in the fuel tank and carburetor, conduct servicing as required in the table below before using again.
Storage Duration | Recommended Servicing Procedure to Prevent Difficult Startups |
Within one month | No preparation needed |
One to two months | Evacuate the fuel and inject fresh fuel |
Two months to one year | Evacuate the fuel and inject fresh fuel |
Drain the fuel from Carburetor Drain Cup 1 | |
Drain the fuel from Sediment Bowl 2 | |
Over one year | Evacuate the fuel and inject fresh fuel |
Drain the fuel from Carburetor Drain Cup 1 | |
Drain the fuel from Sediment Bowl 2 | |
Drain the original fuel into a suitable storage container after moving it out of storage and inject fresh fuel before starting it. | |
1 Loosen and remove the oil drain bolt and drain all the fuel out of the carburetor. Drain the fuel into a suitable container, and screw in and tighten the oil drain bolt. 2 After turning off the Engine Switch, remove the Sediment Bowl, empty the gasoline from the bowl, reinstall the Sediment Bowl and tighten it. |
Errors | Content of Tips | Error Type | Possible Causes | Recovery Methods |
Unable | ![]() | Fuel system | When using gasoline, turn the fuel cap vent valve knob to OFF; When using LPG, the LPG gas cylinder valve is not open. | Turn the fuel cap breather valve knob to "ON" |
![]() | The Engine Switch is in the OFF position | Turn the Engine Switch to "ON" | ||
![]() | There is no fuel left | Refueling | ||
![]() | The generator set was not properly prepared for storage, or the gasoline was not evacuated, or the quality of injected fuel was poor. | Empty the fuel tank and carburetor and refill with fresh fuel | ||
![]() | The fuel filter is blocked. Carburetor faults, ignition failure, or stuck valves, etc. | Send the generator set to your service dealer, or refer to the Service Manual | ||
Oil Alert Indicator stays on | Engine oil system | Low engine oil level. The engine oil alarm system may turn off the engine. | Add engine oil | |
![]() | Electrical system | The spark plug is faulty, dirty or have improper clearance | Adjust the clearance or replace the spark plug | |
![]() | The spark plug has been moistened by the fuel (spilled outside the engine) | Dry the spark plug with air and reinstall it | ||
Oil Alert Indicator stays on | Communication failure | Send the generator set to your service dealer, or refer to the Service Manual | ||
![]() | Lack of battery power or the battery is damaged | Pull by hand to start or replace the battery | ||
![]() Icon stays on | CO exceeding specified standard values | Poor ventilation | Turn off the generator and improve ventilation | |
No | ![]() Icon flashes | AC overload protection | Load-related problems | Remove the problem load, shut down and restart |
![]() Icon flashes | DC overload protection | Load-related problems | Remove the problem load, shut down and restart | |
![]() The icon stays on | Over-temperature protection | The air inlet is blocked or the ambient temperature is too high or the load is too large | Check the air inlet or remove it from the high temperature environment or reduce the load | |
![]() The icon stays on | Battery overtemperature | The air inlet is blocked or the ambient temperature is too high or the load is too large | Check the air inlet or remove it from the high temperature environment or reduce the load |
Communication failure: Communication failures may occur in two specific situations, as detailed below.
Complete machine | Length × width × height | 23.5×11.8×18.7 in/597×300×475 mm |
Net weight | 67.2 lbs/30.5 kg | |
Generator | Type | Inverter generator |
Frequency | 60 Hz | |
Rated voltage | 120 V | |
Rated power | Gasoline: 1,800 W (Peak Value 1,900 W) LPG: 1,600 W (Peak Value 1,700 W) | |
Power factor | 1 | |
DC output voltage | 42–58.8 V | |
Maximum DC output current | 32 A | |
Engine | Engine model | R80N-i |
Engine type | Single cylinder, four-stroke, forced-air cooling, overhead valve | |
Engine displacement | 80 CC | |
Type of fuel | unleaded gasoline/LPG | |
Volume of fuel tank Generator engine oil volume | 4.00 L/1.05 gal. 0.38 L/0.1 gal. | |
Continuous Operation Time (Gasoline) | 3.5 Hr (full load) | |
Noise Level (at a distance of 7 meters) | 56–67 dB (full load) | |
Model of spark plug | A5RTC (TORCH) | |
Start mode | Electric start |