Startup - EcoFlow Smart Generator Dual Fuel User Manual

Hide thumbs Also See for Smart Generator Dual Fuel:
Table of Contents

Advertisement

2.4.1 Startup

Caution
For fuel selection, the generator will use LPG when the LPG hose is connected and gasoline
when the hose is not connected.
a
1. a. To Use Gasoline: Turn the fuel cap vent valve
knob to ''ON'';
b. To Use LPG: Open the LPG cylinder valve;
The generator can be started using any of the four methods below:
a) Electric Start Switch
Press and hold the Electric Start Switch for 2 seconds to execute the start-up program and start up the
generator.
Tips: To save battery power consumption, when the Engine Switch is at the "ON" position, if the generator
fails to start up, the power will be disconnected after 3 mins and the display screen will switch off. In this
situation, press the start button to activate the screen display to then re-enable the Electric Start Switch.
b) Manual start
Pull the Manual Starter Grip until the line tightens and push it by force.
Tips: When doing a manual start, you will need to hold the generator to prevent it from bumping while you
pull the cord. Do not let the starter handle spring back towards the generator. Gently return the handle to
its original position to avoid damaging the starter. When there is battery loss or no battery, the maintenance
door will need to be opened to manually control the choke door when using the LPG manual start.
10
b
Manual start
2. Turn the Engine Switch to "ON".

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents