Control Panel - Vinotemp WINE-MATE WM-4510D Installation, Use & Care Manual

Customizable wine cooling system
Table of Contents

Advertisement

Control Panel

Fig. 2.1 Control panel
1. Evaporator fan speed control
Turn the knob clockwise to the lowest speed position for non-duct
installations; turn counter-clockwise to achieve required air flow CFM for the
duct installations.
2. Humidifier outlet
Plug in your own independent humidifier in the extremely dry conditions.
3. Cellar heater outlet (option)
Plug in your own forced-air electric heater to protect your wine from freezing.
The heater will be turned on when the cellar temperature is below the preset
low cellar temperature.
4. Alarm call connector (option)
Connect the automatic dialer and then plug the provided phone line into your
home phone jack. A
speech notice will be sent to your phones when the cellar
temperature is out of the range.
5. Crankcase heater with fan cycling switch (option)
If the ambient temperature falls below 50°F, switch on the heater.
6. High condenser fan switch
If the ambient temperature rises above 90°F or ducts are installed, switch on
the high condenser fan.
- 7 -