• If the air probe is in a return duct, the evaporator fans shall be running all the
time. Meanwhile due to the temperature differential the air probe calibration
should be used in order to maintain the proper wine cellar temperature.
8. How to adjust defrost cycle
In case there is excessive frost, the parameters FnC = C-y, idF = 4 and MdF =
20 can be used to avoid frost.
9. How to adjust the humidity
The parameter Fon is used to adjust the humidity in the wine cellar. Higher Fon
results in higher relative humidity.
humidity.
10. How to set alarm call
1)
Speech notice will be sent to your phones when the cellar temperature is ALU
higher or ALL lower than the set-point Set.
2) In order to test the call function, set parameters Ald = 0 and dAO = 0. After
testing, set Ald = 60 and dAO = 23.
11. How to set low cellar temperature heater
The heater turns on at SAA minus Shy; the heater turns off at SAA.
NOTES:
• Use a forced air heater to warm up the wine cellar.
• If there is a thermostat on the heater, bypass it or set the thermostat at the
highest level.
If the heater runs more than 10 A current, use a 120VAC coil contactor.
Use a separate hygrometer to monitor the