Summary of Contents for Vinotemp WINE-MATE WM-1500SLIM
Page 1
Wine Cooling Unit Installation, Use & Care Manual WM-1500SLIM WM-1500SLIM-TE Vinotemp International Corp 732 South Racetrack Road, Henderson, NV 89015 Tel: (800) 777-VINO Fax: (310) 886-3310 Email: info@vinotemp.com Read and save these instructions...
Table of Contents Features & Specifications.…………………….……………..3 Installation Instructions..……………………………………..5 Temperature and Humidity……………..…………………..11 Care Guide…………………………………………..………15 Troubleshooting……………………………………………..16 Wiring Diagram……………………………………….………19 Customer Support……………………………………………20 Warranty……………………………………………………….21 - 2 -...
Features and Specifications WM-1500SLIM and WM-1500SLIM-TE cooling units are designed and used to provide a subtle temperature between 50~65 °F for a properly insulated wine cabinet. The humidity in the refrigerated space is maintained within 50~70% RH. These temperature and humidity ranges are optimized for long term storage of wine.
Page 5
The specifications and dimensions are listed as follows: Dimensions (in) Model NO Exhaust Cabinet (cu ft) Electrical Rating Weight (lb) W x D x H Rear 115V/60Hz/4A 18 x 8 x 13.5 1500SLIM 1500SLIM- 115V/60Hz/4A 18 x 8 x 13.5 NOTES: ...
Installation Instructions NOTES: DO NOT USE A GROUND FAULT INTERRUPTER (GFI). A DEDICATED 20 AMP CIRCUIT IS REQUIRED. DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. Mounting brackets, screws, gaskets and other seal materials are not included. ...
Page 7
The cooling unit produces cooling supplied into the cabinet, meanwhile it also generates heat that must be exhausted outside the cabinet. So the cold-air supply with return-air intake and hot-air exhaust with ambient-air side must be separated and sealed. Foam tape gasket may be used to seal them. The cooling unit must intake adequate fresh ambient-air to work properly.
Temperature and Humidity 1. The controller Fig. 3.1 TEMPERATURE CONTROLLER 1) Keys SET: To display set-point; in programming mode it selects a parameter or confirms an operation. : To start a manual defrost. : To see the maximum stored temperature; in programming mode it browses the parameter codes or increases the displayed value.
Page 13
4) Alarm Signals The alarm codes are described as follows. MESSAGE CAUSE FUNCTION Temperature probe faulty Compressor switching to Con and CoF Probe temperature ALU higher than the High temperature alarm setting temperature; Outputs unchanged Probe temperature ALL lower than the Low temperature alarm setting temperature;...
Page 14
6. Parameter Programming 1) Press and hold the SET + keys until the “°C” or “°F” LED starts flashing, then release the keys. 2) Press and hold again the SET + keys until the Pr2 label is displayed, then release the keys. The first parameter Hy will be displayed. 3) Press up/down keys to scroll to the required parameter within 10 sec.
Page 15
In case there is excessive frost, the parameters FnC = C-y, idF = 4 and MdF = 20 can be used to avoid frost. 9. How to adjust the humidity The parameter Fon is used to adjust the humidity in the wine cellar. Higher Fon results in higher relative humidity.
Care Guide 1. Cleaning Condenser Clean the condenser regularly at least every 6 months. Condenser is located on the ambient air intake side of the cooling unit. Use a condenser brush or a vacuum cleaner with an extended attachment to clean the condenser.
Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Complaint Possible Causes Response 1. Unit not a. Power cord not plugged a. Check power cord b. No power from supply b.
Page 18
high or not opening, power cord grommet b. Cellar too large b. Check for excessive size cooling and c. Ambient temperature too high c. Check installation location running d. Exhaust restricted d. Leave minimum 3 feet clearance for continually the hot air exhaust side and leave minimum 1 foot clearance for the fresh air intake side e.
Page 19
b. Low ambient temperature b. Move to another location c. Air probe fault c. Change a new one d. Temperature controller fault d. Change a new one 13.Evaporator a. Evaporator air flow restriction a. Check for fans and air flow b.
Customer Support If you need further assistance, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 20 -...
BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
Page 23
VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.