Honeywell Experion 8 Series Technical Information page 19

Table of Contents

Advertisement

Series 8 Controller and I/O Specification, S803-150-500
Maximum Normal Mode Input (any input
referenced to common, no damage)
Input Scan Rate
Hardware Accuracy (@ CMV = 0 V)
Module Removal and Insertion
Under Power
Transmitter Field Power Conditioning
Note 1 – 8C-PAIH54 supports voltage inputs for channels 1-16 when used with 8C-TAIDx1 IOTA. Each channel's 250-Ohm load
resistor is connected to the input terminal through a wire jumper on the IOTA. This jumper should be cut by the user on
channels to be used with voltage transmitters.
Version 1
± 30 Volts
50 ms
± 0.075% of full-scale (23.5°± 2°C)
± 0.15% of full-scale (0 to 60°C)
Supported
Individually Protected Current Limiting Circuits, No fuse required
19