Fault State; Firmware Update; Self-Check Status; Standby Status - Redx RX Series User Manual

Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

2.Anti-backflow function disabled:
In Auto Mode – the unit can provide power from the Grid and EPS terminals to any loads (max
2500W).When the system detects that there is excess power available from solar and not being
used by the loads and the battery is full, then power can be sent to the grid. In VPP mode:
RX-2505PW works as per the commands sent from the cloud platform. The unit can be fully
customised with charging times and discharging times and set power levels in Timed mode.
B.Off - Grid Functionality
When the power grid is cut off, the system will automatically switch to off-grid mode. The system
will supply power to the load from the battery via the EPS terminals. Note: in off-grid mode, the
maximum system output power is 2500W, meaning the load power of the EPS circuit should not
exceed 2500W;
When the system detects a low battery status, the battery will stop discharging automatically and
will be charged if there is solar or other power supplied.

6.3.2 Fault State

The RX-2505PW has a smart control system that continuously monitors and regulates system status.
When there is a system fault or equipment fault, fault information will be displayed on the web
page /APP, and the LED light will also be on in fault mode.
Notes:
(1) For details about fault information, see Chapter 9.
(2) The fault details inform users of internal faults' possible reasons and rectifications.

6.3.3 Firmware Update

When the system is upgrading firmware, do not power off the unit. When the upgrade is complete,
the system will automatically revert to normal working mode.
6.3.4 Self - Check Status
Before entering normal operation mode, RX - 2505PW will enter self - check mode. If all checks
pass succesfully, the system will return to normal working mode; otherwise, the system goes
into the fault state.

6.3.5 Standby Status

When the system does not fault, but certain operating conditions are not met, the system will go
into standby mode.

6.3.6 Protection Mode

Connecting an over size load to the EPS terminal will trip the unit and trigger protection mode.
The unit will try to restart 3 times, if the load is still present, the unit will revert to protection
mode. Remove the over size load and restart the unit. If any circuit breakers have tripped –
contact your installation partner.

6.3.7 Shutdown Status

Disconnect power supply and the system will automatically convert to standby mode. To shut
down the unit, follow the specific steps below:
1. Turn off the power button.
2. Turn off the battery switch.
3. Disconnect the grid supply, the LED light and the battery power display LED light will be
turned off.
Note: After all the above steps are completed, wait at least 5 minutes before performing other
operations
Rev 20221130