Cleaning The Spark Arrestor; Adjusting The Governor - Champion 500559-EU Operator's Manual

2800w rated portable generator
Table of Contents

Advertisement

500559-EU - 2800W RATED PORTAbLE GENERATOR
Once oil has been added, a visual check should show oil
about 1-2 threads from running out of the fill hole. If using
the dipstick to check oil level, DO NOT screw in the dipstick
while checking.
Cleaning and Adjusting the Spark Plug
1. Remove the spark plug lead from the spark plug.
2. Use a spark plug socket tool (not included), or a
13/16 in. (21 mm) socket (not included) to remove the plug.
3. Inspect the electrode on the plug. It must be clean and not
worn to produce the spark required for ignition.
4. Make certain the spark plug gap is
0.024-0.031 in. (0.6-0.8 mm).
5. Refer to the spark plug types in
replacing the plug.
6. Firmly re-install the plug.
7. Attach the spark plug cable to the spark plug.
Cleaning the Air Filter
1. Remove the snap-on cover holding the air filter to the
assembly.
2. Remove the foam element.
3. Wash in liquid detergent and water. Squeeze thoroughly dry
in a clean cloth.
4. Saturate in clean engine oil.
5. Squeeze in a clean, absorbent cloth to remove all excess
oil.
6. Place the filter in the assembly.
7. Reattach the air filter cover and snap in place.

Cleaning the Spark Arrestor

1. Allow the engine to cool completely before servicing the
spark arrestor.
NOTICE
SPARK PLUG GAP
Specifications
when
2. Remove the two or three screws (varies by model) holding
the cover plate which retains the spark arrestor to the
muffler.
3. Remove the spark arrestor screen.
4. Carefully remove the carbon deposits from the spark
arrestor screen with a wire brush.
* See your model's parts list for specified type of spark arrestor.
5. Replace the spark arrestor if it is damaged.
6. Position the spark arrestor on the muffler and attach with
the screws removed in step 2.
Failure to clean the spark arrestor will result in degraded
engine performance.
If running high load or for long periods of time spark arrestor
maintenance needs to be monthly.
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required.
When ordered, spark arrestors are required for operation
of this generator in National Forest lands. In California,
this generator must not be used on any forest-covered
land, brush-covered land, or grass-covered land unless the
engine is equipped with a spark arrestor.

Adjusting the Governor

Tampering with the factory set governor or any engine
setting will void your warranty.
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. Contact our
Technical Support Team for all other service and/or adjustment
needs.
21
MAINTENANCE
Type 1
CAUTION
NOTICE
WARNING
Type 2
EN