Summary of Contents for Rohde & Schwarz HMP Series
Page 1
® R&S HMP Series Power Supplies Getting Started (;ÜÑé2) 1178679102 Version 03...
Page 2
® This manual applies to the following models and options of the R&S HMP series: ● R&S ® HMP2020 Two-Channel Power Supply (3629.6718.02) ● R&S ® HMP2030 Three-Channel Power Supply (3629.6718.03) ● R&S ® HMP4030 Three-Channel Power Supply (3629.6776.03) ● R&S ®...
® Contents R&S HMP Series Contents 1 Safety and regulatory information........5 1.1 Safety instructions................6 1.2 Labels on the R&S HMP............... 9 1.3 Warning messages in the documentation........10 1.4 Korea certification class A..............11 2 Documentation overview............ 12 2.1 Getting started manual...............12 2.2 User manual..................
Page 4
® Contents R&S HMP Series 4.7 Connecting to power................23 4.8 Connecting to LAN................24 4.9 Connecting a device under test (DUT)..........25 4.10 Switching on and off................26 5 Instrument tour..............28 5.1 Front panel tour.................. 28 5.2 Rear panel tour..................32 6 Trying out the instrument...........
Intended use The products of the R&S HMP series provide adjustable DC voltage, current and power for electrical loads. They are designed for industrial use, e.g. production testing, maintenance and engineering labs.
® Safety and regulatory information R&S HMP Series Safety instructions Safety instructions Products from the Rohde & Schwarz group of companies are manufactured according to the highest technical standards. To use the products safely, follow the instructions provided here and in the product documentation. Keep the prod- uct documentation nearby and offer it to other users.
Page 7
® Safety and regulatory information R&S HMP Series Safety instructions ments where nonconductive contamination can occur. For more information on environmental conditions such as ambient temperature and humidity, see the data sheet. Setting up the product Always place the product on a stable, flat and level surface with the bottom of the product facing down.
Page 8
® Safety and regulatory information R&S HMP Series Safety instructions ● Only use intact cables and route them carefully so that they cannot be dam- aged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables.
® Safety and regulatory information R&S HMP Series Labels on the R&S HMP ● Ensure that all products are grounded by connecting them to the AC power. ● Disconnect all power connections to the product, including outputs. Measurement categories IEC 61010-2-030 defines measurement categories that rate products on their ability to resist short transient overvoltages that occur in addition to the working voltage.
® Safety and regulatory information R&S HMP Series Warning messages in the documentation ● Identification of the product, see the serial number on the rear panel. Table 1-1: Labels regarding the R&S HMP and environment safety Labeling in line with EN 50419 for disposal of electrical and electronic equipment after the product has come to the end of its service life.
® Safety and regulatory information R&S HMP Series Korea certification class A NOTICE Potential risks of damage. Could result in damage to the supported product or to other property. Korea certification class A 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하...
® Documentation overview R&S HMP Series Service manual Documentation overview This section provides an overview of the R&S HMP user documentation. Unless specified otherwise, you find the documents at www.rohde-schwarz.com/manual/ hmp. Further documents are available under www.rohde-schwarz.com/hmp2000 www.rohde-schwarz.com/hmp4000. Getting started manual The getting started introduces the R&S HMP and describes how to set up and...
® Documentation overview R&S HMP Series Release notes and open-source acknowledgment (OSA) https://gloris.rohde-schwarz.com Instrument security procedures Deals with security issues when working with the R&S HMP in secure areas. It is available for download on the Internet. Printed safety instructions Provides safety information in many languages.
® Documentation overview R&S HMP Series Remote control drivers The software makes use of several valuable open source software packages. An open-source acknowledgment document provides verbatim license texts of the used open source software. See www.rohde-schwarz.com/firmware/hmp. Application notes, application cards, white papers, etc.
Key features R&S HMP Series Key features The R&S HMP series power supplies set standards in performance and usability. Outstanding key features are: ● High output power within a minimum space, high efficiency and low-residual ripple. ● High programming and readback resolution for applications with the highest demands.
® Preparing for use R&S HMP Series Choosing the operating site Preparing for use Here, you can find basic information about setting up the product for the first time. Lifting and carrying "Lifting and carrying the product" on page 6.
® Preparing for use R&S HMP Series Setting up the R&S HMP Electromagnetic compatibility classes The electromagnetic compatibility (EMC) class indicates where you can operate the product. The EMC class of the product is given in the data sheet. ● Class B equipment is suitable for use in: –...
Page 18
® Preparing for use R&S HMP Series Setting up the R&S HMP ● It is best if all products have the same dimensions (width and length). If the products have different dimensions, stack according to size and place the smallest product on top.
® Preparing for use R&S HMP Series Considerations for test setup To mount the R&S HMP in a rack 1. Use an adapter kit that fits the dimensions of the R&S HMP to prepare the instrument for rack mounting. a) Order the rack adapter kit designed for the R&S HMP. For the order num- ber, see the data sheet.
Page 20
® Preparing for use R&S HMP Series Considerations for test setup – Double-shielded IEEE-488 (GPIB) bus cables. We recommend that you use the double-shielded cable "R&S HZ72" from Rohde & Schwarz (GPIB- cable 2 m, order no. 3594.4269.02). ● Cables for output supply: –...
® Preparing for use R&S HMP Series Preparing for mains voltage Preparing for mains voltage The R&S HMP is designed for 115 V or 230 V mains voltage. The range is speci- fied on the label below the AC power supply...
Page 22
® Preparing for use R&S HMP Series Preparing for mains voltage 2. Insert a flathead screwdriver with a blade width of approximately 2 mm under the small opening tab of the fuse holder. Figure 4-1: AC power connector 1 = Power supply connector...
® Preparing for use R&S HMP Series Connecting to power To set the supplied mains voltage AC voltage switch selector is at the rear panel. ► To set to 115 V mains voltage, use a tool e.g. a flat screwdriver to slide the voltage selector so that the label indicates 115 V.
® Preparing for use R&S HMP Series Connecting to LAN 4. Plug the AC power cable into a power outlet with ground contact. Do not use a cheater plug or other means to bypass or disconnect the protec- tive ground lead.
For safety information, see "Working with hazardous voltages" on page 8. The R&S HMP series instruments with two, three or four output channels enable you to supply DUTs with power in a wide variety of applications. Getting Started 1178.6791.02 ─ 03...
® Preparing for use R&S HMP Series Switching on and off As a brief introduction, the following example describes the basic steps to be taken when setting up a measurement. For specific applications and setups, see chapter "Application examples" in the user manual.
Page 27
® Preparing for use R&S HMP Series Switching on and off To switch on the R&S HMP The instrument is off but connected to power, see Chapter 4.7, "Connecting to power", on page 23. ► Press the [Power] key at the front panel.
® Instrument tour R&S HMP Series Front panel tour Instrument tour This chapter explains the control elements and the connectors of the R&S HMP instruments. The views of the front panel and the rear panel help you to get famil- iar with the instrument and to perform first steps.
Page 29
® Instrument tour R&S HMP Series Front panel tour Figure 5-1: Front view of the R&S HMP2030 Figure 5-2: Front view of the R&S HMP4040 1 = [Power] key, see Chapter 5.1.1, "[Power] key", on page 30. 2 = Display, see Chapter 5.1.2,...
Page 30
® Instrument tour R&S HMP Series Front panel tour 8 = Channel output connectors, see "CHn" on page 32. 9 = Protective conductor terminal terminal, see "Protective conductor terminal" on page 32. 10 = [Keypad], see System and function keys >...
Page 31
® Instrument tour R&S HMP Series Front panel tour Table 5-2: Channel controls Assigned functions Selects a channel for output. [Ch1] 1,2,3,4) The number of provided channel keys corresponds to the instru- [Ch2] 1,2,3,4) ment model. 2,3,4) [Ch3] [Ch4] [Output] Activates the output of the selected channels.
® Instrument tour R&S HMP Series Rear panel tour Sense 4 mm safety sockets. Two connectors provided for each channel are used for compensating lead resis- tances. 4 mm safety sockets. Depending on the instrument model, the number of output channels (up to four channels) and the voltage and current range varies.
Page 33
® Instrument tour R&S HMP Series Rear panel tour Figure 5-3: Rear view of the HMP20x0 series Figure 5-4: Rear view of the HMP40x0 series Getting Started 1178.6791.02 ─ 03...
Page 34
® Instrument tour R&S HMP Series Rear panel tour 1 = LAN interface, see "LAN" on page 34 2 = USB type B, see "USB B" on page 34 3 = Power supply, see "AC supply with fuse holder" on page 35 4 = Voltage selector, see "AC power supply voltage selector switch"...
Page 35
® Instrument tour R&S HMP Series Rear panel tour Rear panel connector Rear panel output connector for connecting the R&S HMP in 19‘‘ rack systems. Depending on the instrument model, the instrument provides up to two 8-pin con- nector blocks. A connector block covers four lines for voltage, current sense and trigger signals for each channel.
1. Before trying out, observe the safety instructions and maximum specification. For information on the settings and the corresponding remote control commands, see the user manual of the R&S HMP series. Selecting the channels ► Press the channel key, e.g. [Ch1].
Page 37
See chapter "Instrument functions > Basic functions > Key fallback time" in the user manual. Activating the fuse The R&S HMP series includes an electronic fuse function that enables you to pro- tect a connected sensitive test circuit even better from damage. 1. Press the [Fuse] key.
Page 38
® Trying out the instrument R&S HMP Series After the fallback time has elapsed, the instrument exits the setting mode. See chapter "Instrument functions > General functions > Key fallback time" in the user manual. 3. Repeat step 1 and step 2 to disable the fuse function.
® Instrument control R&S HMP Series Means of manual interaction Instrument control This chapter provides an overview on how to work with the R&S HMP. It covers the following topics: ● Ways to operate the instrument..............39 ● Means of manual interaction................
Page 40
® Instrument control R&S HMP Series Means of manual interaction The [rotary knob] allows you to navigate on the home screen or in dialogs, and to set parameters. The [arrow] move the cursor in entry fields. 7.2.1 Understanding the display information ●...
Page 41
® Instrument control R&S HMP Series Means of manual interaction Figure 7-3: Selection list example 7.2.2 Characteristics of setting controls All system and function keys are backlit keys, indicating, e.g. the operating mode of a channel, or an active function.
Page 42
® Instrument control R&S HMP Series Means of manual interaction Function keys Table 7-2: Colors of function keys Color State White The function or operating mode is activated The function or operating mode is not active. Navigation controls The navigation controls include a [rotary knob] and [arrow] keys. They allow you to navigate within a setting, menus or dialogs.
Page 43
® Instrument control R&S HMP Series Means of manual interaction See the user manual, chapter Instrument functions > General functions > Key fall- back time . Numerical Keypad The instrument models R&S HMP4030 and R&S HMP4040 provide a keypad on the font panel, to enter numerical values.
® Instrument control R&S HMP Series Entering data 3. Press the [rotary knob] to confirm the selection. The selected dialog opens. To select a parameter in a dialog 1. Open the dialog as described in "To open a dialog" on page 43.
® Instrument control R&S HMP Series Remote control 5. Turn the [rotary knob] to increase or decrease the value. Alternatively, use the [up] and [down] keys. 6. Press the [rotary knob] to confirm the value. Values adjusted with the keypad must be applied with the [Enter] key. Other- wise, the instrument disables the edit mode without the changes taking effect.
® Contacting customer support R&S HMP Series Contacting customer support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz product, contact our customer support center. A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation, program- ming or applications of Rohde &...
® Index R&S HMP Series Index Considerations Setting up ..........19 AC power supply Customer support ........46 Rear panel .......... 35 AC supply How to connect ........23 Data entry ..........44 Access Data sheet ..........13 Instrument ........... 43 Display Activating the fuse ........
Page 48
® Index R&S HMP Series Select the supplied mains voltage ..23 Manual interaction ........39 Unmount in a rack .......19 Manual operation ........39 Measurement controls ......31 Mounting in a rack ........18 Illuminated keys ........28 Instrument Carrying ..........16 Navigation controls ........
Page 49
® Index R&S HMP Series Remote control ........39, 45 Selecting the current limit ....37 Drivers ..........14 Selecting the output voltage ....36 Interfaces ..........45 Replace the line fuse How to: ..........21 Unpacking the instrument ......16 RS-232 USB B Connector ...........
Need help?
Do you have a question about the HMP Series and is the answer not in the manual?
Questions and answers