Download Print this page

Installation - Mitsubishi Electric MELSEC-F FX3U User Manual

Advertisement

JY997D36701E
FX
-2HC
3U
USER'S MANUAL
Manual Number
JY997D36701
Revision
E
Date
March 2019
This manual describes the part names, dimensions, mounting, wiring, and
specifications of the product. Before use, read this manual and the manuals of all
relevant products fully to acquire proficiency in handling and operating the product.
Make sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company names, system names and product names mentioned in this manual
are either registered trademarks or trademarks of their respective companies.
In some cases, trademark symbols such as '
' or '
' are not specified in this manual.
Effective March 2019
Specifications are subject to change without notice.
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
3U
Series
JY997D16501
Explains the FX
3U
Series PLC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
- Hardware Edition
09R516
installation, and maintenance.
FX
Series
JY997D28701
Explains the FX
Series PLC
3UC
3UC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
- Hardware Edition
09R519
installation, and maintenance.
FX
/FX
/FX
/
3S
3G
3GC
Describes FX
/FX
/FX
3S
3G
FX
/FX
Series
JY997D16601
3U
3UC
FX
3UC
Series PLC programming for
Programming Manual
MODEL CODE:
basic/applied instructions and
- Basic & Applied
09R517
devices.
Instruction Edition
MELSEC iQ-F FX5U
JY997D55301
Explains the FX5U PLC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
(Hardware)
09R536
installation, and maintenance.
MELSEC iQ-F FX5UC
JY997D61401
Explains the FX5UC PLC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
(Hardware)
09R558
installation, and maintenance.
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
Certification of UL, cUL standards
The following product has UL and cUL certification.
UL, cUL File Number:E95239
Models:
MELSEC FX
series manufactured
3U
from December 1st, 2009
FX
-2HC
3U
WIRING
PRECAUTIONS
 Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
PLC under the influence of noise:
1) Do not bundle the main circuit line together with or lay it close to the main
circuit, high-voltage line or load line. Otherwise, noise disturbance and/or
surge induction are likely to take place. As a guideline, lay the control line at
least 100mm (3.94") or more away from the main circuit or high-voltage lines.
2) Ground the shield wire or shield of the shielded cable at two points; on the
PLC and the device on other end. However, do not use common grounding
with heavy electrical systems.
3.1 Connection to input/output connector
The input and output connectors conform to the MIL-C-83503.
For the input and output connectors pin assignment, refer to section 1.4.
1) Compliant connectors (commercially available connectors)
Use a 40-pin (1-key) socket connector conforming to MIL-C-83503.
Confirm in advance that the connectors do not interfere with other parts
including connector covers.
2) Connectors for user-made input/output cables (available from Mitsubishi)
Users should provide electric wires and a pressure bonding tool.
Applicable electric wire
Model name and composition of
(UL-1061 are recommended)
input/output connector
and tool
Electric
Our model
Details of part
Pressure bonding tool
wire
name
(made by DDK Ltd.)
(made by DDK Ltd.)
size
FX-I/O-CON2-S
Housing:HU-400S2-001
AWG22
for bulk wire
Solderless contact:
357J-5538
2
(0.3mm
)
(2-piece set)
HU-411S
FX-I/O-CON2-SA
Housing:HU-400S2-001
AWG20
for bulk wire
Solderless contact:
357J-13963
2
(0.5mm
)
(2-piece set)
HU-411SA
3.2 Wiring
Note:
Make sure to properly wire in accordance with the encoder output specifications.
Incorrect wiring may cause accidents or damage to the product.
3.2.1
NPN output encoders
FX
3U
FX
*1
Encoder (NPN)
3UC
24V DC
Class D
+24V
FX
-2HC
3U
3.3k
0V
*1
A24+
1.5k
Shielded
A12+
Twisted-Pair
0.2k
A 5+
0.12k
Phase
A -
A
*2
Class D
Class D
Shielded
1.65k
*1
*3
XD24
Twisted-Pair
DISABLE
0.47k
XD 5
0.22k
COMD
3.3k
*1
P24+
Class D
1.5k
P12+
0.2k
Phase
P 5+
Z
0.12k
Shielded
*3
P -
PRESET
Twisted-Pair
Class D
Class D
*1.
Drive power supply of the encoder.
Use either 24V DC, 12V DC, or 5V DC according to the encoder type.
When connecting the A phase, the B phase, and the Z phase to the
FX
-2HC, connect to the power supply terminal.
3U
When using 24V DC for PRESET or DISABLE signals, connect to the 24V
DC (P24+, XD24) terminal
*2.
Wiring of the B phase is the same as that of the A phase.
*3.
This wiring is unnecessary when not using the PRESET function or the
DISABLE function.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more details please contact the
local Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
series manufactured
3U
from December 1st, 2009
FX
-2HC
3U
Standard
EN61131-2:2007
Compliance with all relevant aspects of the standard.
Programmable controllers
EMI
- Equipment requirements
• Radiated Emission
and tests
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Caution for EC Directive
 Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Please secure the cabinet
door to the control cabinet (for conduction). Installation within a control cabinet
greatly affects the safety of the system and aids in shielding noise from the
programmable controller.
1. Outline
1.1 Outline
The hardware high-speed counter block is a 2-channel high-speed counter. It is a
special function block for the FX
/FX
/FX5U/FX5UC PLC.
3U
3UC
1.2 Major Features of the FX
-2HC
3U
may
 Differential-Line-Driver (AM26C31 or equivalent) and open collector output
encoders are available for the FX
3U
-2HC.
 The FX
-2HC has two outputs per channel. When the counter value coincides with
3U
an output compare value, the appropriate output is set ON. The output transistors
are individually isolated to allow either sink or source connection methods.
 Various counter modes, such as 1-phase or 2-phase, 16-bit or 32-bit modes, can be
selected using commands in the sequence program. Allow the FX
run only after setting these mode parameters.
1.3 Incorporated Items
Verify that the following product and items are included in the package:
Included Items
FX
-2HC
3U
/FX
/
3GC
3U
Special unit/block No. label
Dust proof protection sheet
Manuals [Japanese version]
Manuals [English version] (This manual)
1.4 External Dimensions, Part Names, and Terminal Layout
[2]
[3] [4]
2-φ4.5 mounting holes
[1]
[9]
[8]
9 (0.36")
4 (0.16")
87 (3.43")
55 (2.17")
Weigh: Approx. 0.2 kg (0.44 lbs)
3.2.2
PNP output encoders
*1
FX
24V DC
3U
FX
3UC
Class D
Shielded
FX
-2HC
3U
Twisted-Pair
3.3k
*1
A24+
1.5k
A12+
0.2k
A 5+
0.12k
Class D
Class D
A -
*2
Shielded
Twisted-Pair
DISABLE
1.65k
*1
XD24
0.47k
XD 5
0.22k
COMD
Class D
3.3k
*1
P24+
1.5k
P12+
0.2k
Shielded
P 5+
Twisted-Pair
0.12k
Class D
P -
*1.
Drive power supply of the encoder.
Use either 24V DC, 12V DC, or 5V DC according to the encoder type.
When connecting the A phase, the B phase, and the Z phase to the
FX
3U
-2HC, connect to the power supply terminal.
When using 24V DC for PRESET or DISABLE signals, connect to the 24V
DC (P24+, XD24) terminal.
*2. Wiring of the B phase is the same as that of the A phase.
*3.
This wiring is unnecessary when not using the PRESET function or the
DISABLE function.
3.2.3
Differential-Line-Driver output encoders
When applying the Differential-Line-Driver encoder (AM26C31 or equivalent) to the
FX
-2HC, connect the encoder output with the 5V DC terminal as shown in the figure
3U
below.
5V DC
FX
3U
*1
FX
3UC
Class D
FX
-2HC
3U
0.2k
A 5+
0.12k
A -
*1
0.47k
*2
XD 5
0.22k
COMD
0.2k
P 5+
0.12k
P -
*1.
Wiring of the B phase is the same as that of the A phase.
*2.
This wiring is unnecessary when not using the PRESET function or the
DISABLE function.
3.2.4
YH1, YH2 output wiring [Sink wiring]
FX
-2HC
3U
YH1+
YH1-
YH2+
YH2-
Fuse
Output load driving
power, 5 - 24V DC
Caution
A protection fuse should be inserted at the output.
Use a load power supply capacity that is at least 2 times larger than the total rated
fuse capacity.
No.
Direct mounting hole: 2 holes of
[1]
Used when attaching FX
Extension cable (PLC side)
[2]
Used to connect this special function block to the FX
extension block.
[3]
CH1 connector
[4]
CH2 connector
Status LED (the upper side: CH1, the lower side: CH2)
POWER
Power LED
(Green)
UP (Red)
Up count LED
DOWN (Red)
Down count LED
Remark
A phase input LED
A (Red)
[5]
B phase input LED
B (Red)
DIS (Red)
DISABLE input LED T h e r e s p e c t i v e L E D i s O N / O F F
PRE (Red)
PRESET input LED
YH1 (Red)
YH1 output LED
YH2 (Red)
YH2 output LED
[6]
Top cover
Extension connector (Extension side)
[7]
Used to connect a FX
block. Remove top cover for connecting.
[8]
DIN rail mounting hook
[9]
DIN rail mounting groove (DIN rail: DIN46277, 35mm (1.38") width)
FX
3U
A24+
Phase A
A5+
input
B24+
Phase B
input
B5+
PRESET
P24+
input
P5+
-2HC unit to
3U
XD24
DISABLE
input
YH1 output
YH1+
YH2 output
YH2+
1 Unit
1 Sheet
1 Sheet
1 manual
1 manual
2. Installation, Connect to the PLC

INSTALLATION

PRECAUTIONS
Without top cover
 Make sure to cut off all phases of the power supply externally before attempting
[5]
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
[5]
PRECAUTIONS
[6]
 Use the product within the generic environment specifications described in PLC
[5]
main unit manual.
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
impacts, or expose it to high temperature, condensation, or rain and wind.
[7]
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
3.2.5
YH1, YH2 output wiring [Source wiring]
Encoder (PNP)
FX
3U
-2HC
YH1+
+24V
*1
YH1-
0V
YH2+
Phase
A
YH2-
Caution
A protection fuse should be inserted at the output.
Use a load power supply capacity that is at least 2 times larger than the total rated
fuse capacity.
*2
3.3 Grounding
Grounding should be performed as stated below.
*3
 The grounding resistance should be 100 or less.
 Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding"
of the following figure.
For details, refer to the FX
For details, refer to the FX
Phase
For details, refer to the MELSEC iQ-F FX5U User's Manual (Hardware).
Z
For details, refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).
*3
Another
PRESET
PLC
equipment
Class D
Independent grounding
Best condition
 The grounding wire size should be AWG 22-20 (0.3-0.5 mm
 The grounding point should be close to the PLC, and all grounding wires
should be as short as possible.
4. Specifications
DESIGN
PRECAUTIONS
 Make sure to have the following safety circuits outside of the PLC to ensure safe
system operation even during external power supply problems or PLC failure.
Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection
circuit, an interlock circuit for opposite movements (such as normal vs.
Encoder
reverse rotation), and an interlock circuit (to prevent damage to the
equipment at the upper and lower positioning limits).
+5V
2) Note that when the PLC CPU detects an error, such as a watchdog timer
error, during self-diagnosis, all outputs are turned off. Also, when an error that
0V
cannot be detected by the PLC CPU occurs in an input/output control block,
output control may be disabled.
External circuits and mechanisms should be designed to ensure safe
LA
machinery operation in such a case.
3) Note that when an error occurs in a relay, triac or transistor output device, the
LAR
output could be held either on or off.
For output signals that may lead to serious accidents, external circuits and
*1
mechanisms should be designed to ensure safe machinery operation in such
a case.
*2
DESIGN
DISABLE
PRECAUTIONS
LZ
 Do not bundle the control line together with or lay it close to the main circuit or
LZR
power line. As a guideline, lay the control line at least 100mm (3.94") or more
*2
PRESET
away from the main circuit or power line.
Noise may cause malfunctions.
 Install module so that excessive force will not be applied to I/O connectors.
Failure to do so may result in wire damage/breakage or PLC failure.
4.1 General Specifications
The general specifications are equivalent to the PLC main unit.
(For general specifications, refer to the manual of the PLC main unit.)
Caution
When a dielectric withstand test of this product is performed, ground all terminals of
this product and the PLC unit.
4.2 Power Supply Specifications
Item
Units driving power
Allowable instantaneous
power failure time
INSTALLATION
Name
PRECAUTIONS
4.5 (0.18") (mounting screw: M4 screw)
 Do not touch the conductive parts of the product directly.
-2HC directly.
3U
 Install the product on a flat surface.
3U
/FX
3UC
main unit or an
 When drilling screw holes or wiring, make sure cutting or wire debris does
 Be sure to remove the dust proof sheet from the PLC's ventilation port when
ON when the 5V power supply is
normally supplied from the PLC.
 Connect extension cables securely to their designated connectors.
The respective LED is ON according
to up/down count direction of the
counter.
2.1 Mounting
The respective LED is ON (flicker)
The product is mounted by the following method.
according to ON/OFF of
A and
B
 DIN rail mounting
input.
 Direct mounting (mounting screw: M4 screw)
For further information on installation arrangements, refer to the following manuals.
according to ON/OFF of PRESET and
DISABLE input.
T h e r e s p e c t i v e L E D i s O N / O F F
according to status of YH1 and YH2
2.1.1
output.
The product can be mounted on a DIN rail
(DIN46277, 35mm (1.38") width).
1) Fit the upper edge of the DIN rail mounting
3U
extension block to the right of this special function
2) Press the product against the DIN rail.
-2HC connector arrangement
CH1
CH2
A12+
A24+
A12+
2.1.2
A-
A5+
A-
The product can be installed directly with screws.
Refer to the External Dimensions (section 1.4) for the product's mounting hole
pitch information.
B12+
B24+
B12+
An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary.
B-
B5+
B-
2.2 Connection to the PLC
P12+
P24+
P12+
A maximum of eight
P-
P5+
P-
right side of the powered extension unit/block. A unit number of No.0 to No.7 is
assigned based on the order in which special function units/blocks are attached to
Notch
Notch
the main unit.
For connection to an FX
XD5
XD24
XD5
FX
2NC
COMD
COMD
For connection to an FX5U or FX5UC PLC, an FX5-CNV-BUS or FX5-CNV-BUSC
is required.
YH1-
YH1+
YH1-
*1 Up to seven special function units/blocks in total can be connected to the
YH2-
YH2+
YH2-
*2 Up to two special function units/blocks in total can be connected to the
For further information on installation arrangements, refer to the following manuals.
3. Wiring
WIRING
PRECAUTIONS
 Make sure to cut off all phases of the power supply externally before
 When drilling screw holes or wiring, make sure cutting or wire debris does
, H
S, SO
, or NO
), flammable gas, vibration or
2
2
2
2
4.3 Performance Specifications
Output load
driving power,
5 - 24V DC
Fuse
Series User's Manual - Hardware Edition.
3U
Input
Series User's Manual - Hardware Edition.
3UC
signal
Another
Another
PLC
PLC
equipment
equipment
Shared grounding
Common grounding
Good condition
Not allowed
2
).
Count-
ing spec-
ification
Output
signal
I/O occupation
4.4 Applicable PLC
FX
FX
FX5U PLC
Specifications
FX5UC PLC
5V DC, 245mA (Internal power supply from main unit
or extension power supply unit)
*1 An FX
Operation can be continued upon occurrence of
*2 An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect the FX
instantaneous power failure for 1 ms or less.
*3 The version number can be checked by reading the last three digits of
Doing so may cause device failures or malfunctions.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
installation work is completed.
Failure to do so may cause fire, equipment failures or malfunctions.
Loose connections may cause malfunctions.
Refer to the FX
Series User's Manual - Hardware Edition.
3U
Refer to the FX
Series User's Manual - Hardware Edition.
3UC
Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).
Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).
DIN Rail Mounting
1)
groove (fig. A) onto the DIN rail.
A
- An interval space of 1 to 2 mm (0.04" to
0.08") between each unit is necessary.
Direct Mounting (mounting screw: M4 screw)
*1*2
FX
3U
-2HC(s) are connectable with the main unit or the
Series PLC or FX
Series PLC extension block, an
3UC
2NC
-CNV-IF or FX
-1PS-5V is required.
3UC
FX
-32MT-LT(-2) PLC. Unit numbers assigned to special function units/
3UC
blocks begins with No.1.
FX5U or FX5UC PLC. Unit numbers assigned to special function units/
blocks begins with No.2.
Refer to the FX
Series User's Manual - Hardware Edition.
3U
Refer to the FX
3UC
Series User's Manual - Hardware Edition.
Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).
Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Item
Specification
[A24+],[B24+],
24V DC10%,
[P24+]
8mA or less
Phase A,
[A12+],[B12+],
12V DC10%,
Phase B,
Signal
[P12+]
8mA or less
PRESET
level
(Selected
[A5+],[B5+],
3.0V to 5.5V DC,
by terminal
[P5+]
12.5mA or less
connec-
10.8V to 26.4V DC,
tion)
[XD24]
15mA or less
DISABLE
5V DC10%,
[XD5]
8mA or less
1 input
1 - p h a s e
input
2 input
200kHz
MAX.
1 edge count
frequency
2 - p h a s e
2 edge count
100kHz
input
4 edge count
50kHz
t1
t1
t2
t3
t4
t4
Pulse
shape
t1(ON/OFF pulse):
1.5s or more (at 200kHz)
t2(Phase difference between A and B):
0.75s or more (at 200kHz)
t3(Overlap time):
0.7s or more (at 200kHz)
t4(Rise/fall time):
0.75s or less
PRESET(Z phase) input signal width:
ON width 1.5s or more,
OFF width 30s or more
DISABLE (count prohibit) input signal width:
ON width 100s or more,
OFF width 100s or more
Automatic UP/DOWN
However, when on 1-phase 1-input mode, UP/
DOWN is determined by the following.
Format
 Hardware UP/DOWN: Up/down count is decided
by OFF/ON of the A-phase input terminal.
 Software UP/DOWN: Up/down count is decided
by the current value (K0/K1) of BFM #1, #41.
When 32-bit is specified:
-2,147,483,648 to +2,147,483,647
Range
When 16-bit is specified: 0 to 65,535
(upper limit is set up by BFM #3, #2, #43, #42.)
When the present value and the comparison set
Compari-
value of the counter are equal, the comparison
son Type
output is set (ON) within 30 ms and is cleared (OFF)
within 100 ms by the reset command.
YH1+: transistor output for
YH1 output
YH1-: transistor output for
Types of
YH1 output
outputs
YH2+: transistor output for
YH2 output
YH2-: transistor output for YH2 output
Output
5V ~ 24V DC, 0.5A
capacity
8 points (can be either inputs or outputs)
Model name
Applicability
*3
3U
Series PLC
Ver. 2.20 and later
*1
*3
Series PLC
Ver. 2.20 and later
3UC
*2
From first production
*2
From first production
2NC
-CNV-IF or FX
3UC
-1PS-5V is necessary to connect the FX
2HC with the FX
3UC
PLC.
2HC with the FX5U/FX5UC PLC.
device D8001/D8101.
2)
YH1+,
YH2+
YH1-,
YH2-
3U
-
-
3U

Advertisement

loading

This manual is also suitable for:

Melsec-f fx3u-2hc