UNIT CONTROLLER (PC-ARFH1E)

8.6.2 Advanced Configuration

Select the advance configuration for a complete configuration.
Press OK button.
Select the controller type:
Unit: the device controls the unit.
-
-
Room: the device acts as a room thermostat of a zone.
-
Unit + Room: the device controls the unit and acts as a room thermostat.
Select controlled circuits by this device: Room C1, Room C2, Room C1+C2
Select the favourite action: Eco/Confort, Timer, Night shift.
Select Enabled or Disabled for European summer time.
Select Next and press OK button .
Configure circuit 1 and circuit 2 OTC: Disabled, Points, Gradient, Fix.
Enable or disable DHW and Swimming Pool.
Select the heating source: HP only, HP + EH, HP + Boiler.
Configure electrical heater use: Starting or Backup.
Configure Boiler type: Parallel or Serial.
Configure Solar Combination options: Disabled, Input Demand, Total Control. (only in case DHW is enabled).
Enable or disable Hydraulic separator status.
Select Next and press OK button.
138
PMML0575 rev.2 - 03/2022