Braeburn ECONOMY Series Installer Manual

Braeburn ECONOMY Series Installer Manual

Non-programmable thermostats
Hide thumbs Also See for ECONOMY Series:

Advertisement

Quick Links

Installer Manual
Non-Programmable Thermostats
1030 1 Heat / 1 Cool Conventional
1230 Up to 2 Heat / 1 Cool
1 Specifications
4 Quick Reference 5 Installer Settings 6 System Testing
Warning
For installation by experienced service technicians only.
Caution
Possible electric shock or damage to equipment can occur.
Disconnect power before beginning installation.
This thermostat requires 24 Volt AC Power or 2 properly installed "AA" Alkaline batteries for
proper operation. When connecting 24 Volt AC Power, the batteries may be installed as a backup.
For use only as described in this manual. Any other use will void warranty.
This manual is for Installer use only - do not leave with end user.
1
SPECIFICATIONS
This thermostat is compatible with:
• Single stage conventional and heat pump systems
• Single stage heat pumps with auxiliary heat
• 250 – 750 millivolt heating only systems
• 2 wire hydronic zone systems
Electrical and Control Specifications
• Electrical Rating: 24 Volt AC
• 1 amp maximum load per terminal
• AC Power: 18 – 30 Volts AC
• DC Power: 3.0 Volt DC
(2 "AA" Alkaline Batteries Included)
• Control Range: 45° to 90° F (7° to 32° C)
• Temperature Accuracy: +/- 1° F (+/- .5° C)
or Heat Pump
Conventional or Heat Pump
Model number is located on back of thermostat.
2 Installation
®
3 Wiring
Terminations
1030: Rc, Rh, W1, Y1, G, O, B, C
1230: Rc, Rh, W1/E, W2, Y1, G, O, B, L, C
E
CONOMY
S
ERIES
1030-100-01

Advertisement

Table of Contents
loading

Summary of Contents for Braeburn ECONOMY Series

  • Page 1 ® Installer Manual CONOMY ERIES Non-Programmable Thermostats 1030 1 Heat / 1 Cool Conventional or Heat Pump 1230 Up to 2 Heat / 1 Cool Conventional or Heat Pump Model number is located on back of thermostat. 1 Specifications 2 Installation 3 Wiring 4 Quick Reference 5 Installer Settings 6 System Testing Warning...
  • Page 2: Installation

    2 INSTALLATION Warning Disconnect power before beginning installation. Thermostat Location Install the thermostat approximately 5 feet (1.5m) above the floor in an area that has a good amount of air circulation and maintains an average room temperature. Avoid installation in locations where the thermostat can be affected by drafts, dead air spots, hot or cold air ducts, sunlight, appliances, concealed pipes, chimneys and outside walls.
  • Page 3 2 INSTALLATION Provide Power Batteries Installed as Shown 24VAC Power Terminal (C) • Battery Power - Insert the 2 supplied “AA” type alkaline batteries into the battery compartment located in the rear housing of the thermostat. Make sure to position the Positive (+) and Negative (-) sides of the batteries correctly with the +/- symbols in the battery compartment.
  • Page 4 3 WIRING Conventional and Heat Pump Systems Typical Wiring Configurations NOTE: Make sure installer system selection C ONVENTIONAL H EAT PUMP switch is properly set to CONV or HP. See Section 2. 1030 / 1230 1230 1030 / 1230 1230 Wiring Heat Only 1 Heat/...
  • Page 5: Quick Reference

    4 QUICK REFERENCE Thermostat and Display SYSTEM Switch ..... Selects the system you want to control FAN Switch ......Selects the system fan mode Up / Down Arrow Buttons ..Increases or decreases settings MENU Button ......Used to access thermostat User / Installer setting modes Room Temperature ....
  • Page 6: Installer Settings

    INSTALLER SETTINGS The Installer Settings must be properly configured in order for this thermostat to operate correctly. The Installer Settings are menu driven. The portion of these settings that do not apply to your setup will be skipped. To Enter Installer Settings Menu 1 Press and hold down the MENU button for 5 seconds.
  • Page 7 5 INSTALLER SETTINGS No. Installer Setting Displayed Default Available Description of Setting Settings Available Settings HIGH COOL 90 - 45 Select a Cool Setpoint Upper Limit of 90° to Cool Setpoint Upper Limit (32˚ to 7˚C) 45°F (32° to 7°C) Selects the upper setpoint adjustment limit that cannot be exceeded in cool mode. Installer Lock INST NO...
  • Page 8: System Testing

    Montgomery, IL 60538 Installer - store this manual for future reference Braeburn Systems LLC 2215 Cornell Avenue • Montgomery, IL 60538 Technical Assistance: www.braeburnonline.com Call us toll-free: 866-268-5599 (U.S.) 630-844-1968 (Outside the U.S.) 1030-100-01 ©2022 Braeburn Systems LLC • All Rights Reserved.

This manual is also suitable for:

10301230

Table of Contents