Braeburn 5200 User Manual

Braeburn 5200 User Manual

Premier series universal 7 day or 5-2 day programmable 2 heat/2 cool heat pump digital thermostat
Hide thumbs Also See for 5200:

Advertisement

MODEL
5200
USER MANUAL
Compatible with low voltage multi-stage heat
pump systems with up to two stages of heating
and two stages of cooling. Not for use on
single-stage heating or cooling systems.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
CONTENTS
1

SPECIFICATIONS

2
INSTALLATION
3
TESTING YOUR NEW THERMOSTAT
4
PROGRAMMING USER SETTINGS
5
ADDITIONAL OPERATION FEATURES
6
TROUBLESHOOTING
7
WIRING DIAGRAM
© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5200-100-008
Premier Series
Universal 7 Day or 5-2
Day Programmable
2 Heat/2 Cool Heat Pump
Digital Thermostat
WARNING!

Important Safety Information

• Always turn off power to the air conditioning or heating system prior to installing, removing,
cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating this thermostat.
• This thermostat is designed for use with a 24 Volt AC low voltage multi-stage heat pump system.
• Do not use this thermostat on systems with voltages higher than 30 Volts AC.
• This thermostat requires 24 Volt AC Power for normal operation and control of the heating or
cooling system.
• The thermostat also requires two (2) properly installed "AA" alkaline batteries to retain clock
settings in the event of loss of AC Power due to power outage or rolling blackouts.
• Wiring must conform to all building codes and ordinances as required by local and national code
authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system
control board to test the thermostat installation. This could damage the thermostat and void
the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F (10˚ C). This
could possibly damage the controlled cooling system and may cause personal injury.
• This thermostat should only be used as described in this manual. Any other use is not
recommended and will void the warranty.
1
SPECIFICATIONS
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
3 amp maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• DC Back-Up Power: 3.0 Volt DC (2 AA Alkaline batteries included)
• Compatibility: Multi-stage heat pump systems with up to two stages
of heating and two stages of cooling
• Terminations: R, Y1, Y2, W1, W2, E, G, O, B, L, C
2
INSTALLATION
Replacing Existing Thermostat
2.1
1. Always turn off power to the air conditioning or heating system prior to removing
existing thermostat.
2. Remove the cover of your old thermostat and locate the wire terminals. Do not remove
wires from terminals yet.
3. Using small pieces of masking tape, label wires prior to removal from terminals. Use
the chart below to determine the new terminal designations for your new thermostat.
Old Terminal from
New Terminal for
Existing Thermostat
New Thermostat
R, V-VR or VR-R
R
Y, Y1 or M
Y1
Y2
Y2
W1, W2 or W-U
W2
E
E
G or F
G
O or R
O
B
B
L or X
L
C, X or B
C
Terminal Description
24 Volt AC
Stage 1 Cooling or Heating
Stage 2 Cooling
Stage 2 Heating
Emergency Heating
Fan Control
Reversing Valve (Cooling)
Reversing Valve (Heating)
System Status LED
24 Volt AC, Transformer Common
1

Advertisement

Table of Contents
loading

Summary of Contents for Braeburn 5200

  • Page 1: Important Safety Information

    Fan Control O or R Reversing Valve (Cooling) Reversing Valve (Heating) L or X System Status LED C, X or B 24 Volt AC, Transformer Common © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5200-100-008...
  • Page 2: Installation

    INSTALLATION INSTALLATION cont. cont. Replacing Existing Thermostat cont. 17. Open front thermostat door and open battery compartment door. 18. Install two new "AA" alkaline batteries into battery compartment. Make sure to locate 4. After labeling and removing all wires from terminals, unscrew the existing thermostat the positive (+) ends of the batteries and match them with the positive (+) sub-base from wall.
  • Page 3: User Settings

    PROGRAMMING PROGRAMMING USER SETTINGS USER SETTINGS cont. Default Thermostat Settings Setting the First and Second Stage Differentials 4.3.1 Function Status After Reset First Stage Differential Operation Mode Normal Operating Mode The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from Temperature Hold Extended and Temporary Hold Cleared the setpoint temperature before the thermostat will initiate the system in heating or cooling.
  • Page 4: Programming User Settings

    PROGRAMMING PROGRAMMING USER SETTINGS USER SETTINGS cont. cont. Setting Your Energy Saving Programs Setting the Extended Hold Time (see also section 5.3) cont. 4.3.3 The default setting is Long (indefinite) Hold. If the HOLD feature is activated, the current setpoint will be held until HOLD is released. Time: 6:00 am Time: 6:00 am Heat: 70˚...
  • Page 5 PROGRAMMING PROGRAMMING USER SETTINGS USER SETTINGS cont. cont. Setting Your Energy Saving Programs Setting Your Energy Saving Programs cont. cont. Programming Overview For Weekday/Weekend Programming Mode IMPORTANT NOTE! 4.4.3 When in group (Programming switch set to 5-2 day - see installation section) selection, the thermostat will check if all of the days of that group have the same program Your thermostat contains separate Weekday and Weekend Program Groups that allow you to...
  • Page 6: Additional Operation Features

    Auxiliary Heat Fossil Fuel Switch or after 4 hours – whichever comes first. The Model 5200 is equipped with an auxiliary heat option switch which is set at Extended Hold (Vacation) Mode installation for either an electric or fossil fuel (gas, oil or propane) auxiliary heat source.
  • Page 7: Compressor Protection And Ac Power Monitor

    ADDITIONAL ADDITIONAL OPERATION FEATURES OPERATION FEATURES cont. cont. Multi-Colored LED Status Indicators Compressor Protection and AC Power Monitor 5.11 The three multi-colored LED Status Indicator located on the front of your thermostat above the This thermostat includes an automatic compressor protection feature to avoid potential display will notify you of key system information.
  • Page 8 TROUBLESHOOTING TROUBLESHOOTING cont. cont. SYMPTOM POTENTIAL SOLUTION SYMPTOM POTENTIAL SOLUTION Thermostat will not Check current time of day, day of week program settings. Make Thermostat display It is possible that AC power is not present at the thermostat and sure to verify AM/PM indicator is accurately displaying desired the back-up batteries are fully discharged.
  • Page 9: Wiring Diagram

    2. Eliminate connection to Y2 for units with single stage cooling. Technical Assistance: www.braeburnonline.com 3. Make O or B connections as required by unit. Call us toll-free: 866-268-5599 (U.S. Only) 630-844-1968 (Outside the U.S.) © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5200-100-008...