Refrigerant; Recycling - Orca ZEUS ZSW 230 Installation, Maintenance And User Manual

Domestic hot water heat pump
Hide thumbs Also See for ZEUS ZSW 230:
Table of Contents

Advertisement

User manual

6 REFRIGERANT

The unit is prefilled with HFC R134a refrigerant. The refrigerant is non-toxic, non-flammable and not explosive,
is also not harmful to the ozone layer, but is heavier than air, which can lead to a crowding-out of air from the
area. The result may be smaller concentration of oxygen in the air, but because of a very small amount of
refrigerant in the unit, there are no serious health risks. A reduced concentration of oxygen can occur only in
unventilated areas less than 10 m3 volume. Nevertheless, we recommend that you read the manufacturer's
refrigerant safety sheet and handle in accordance with the written instructions.
DANGER!
Refrigerant leakage can cause serious frostbite. In case of refrigerant leakage immediately
disconnect power supply and inform the authorized customer service. Do not approach the device,
only when necessary (to disconnect the power supply).

7 RECYCLING

1. Waste Product: Consult the manufacturer regarding recycling or disposal.
2. Contaminated packaging: reuse or recycle after decontamination.
3. Removing the refrigerant must be performed in accordance with EC Directive 842/2006, as well as other
national and local regulations.
DISPOSAL INSTRUCTIONS!
The unit must be replaced and disposed according to local regulations; it contains environment
potentially harmful gasses.