WARNING!
Condensate pipe must be checked and cleaned once per month.
DANGER!
The supply socket must be positioned at least 1,5m above ground level, to avoid direct water spray
causing injuries or damage. The socket must be earthed, secured with a 16A fuse and FI relay with
max. current 0,03A. The wire cable to the socket needs to be at least 3x2,5 mm, only the heat pump
can be connected to the socket.

12.1 Galvanic cell

DANGER!
Prevent corrosion due to formation of a galvanic couple, the heat pump must be properly
connected to the system. Fittings are enclosed with the heat pump to connect the cold and hot
water pipes to the heat pump.