7.11 Connection of FCUA-DX13* Unit and Handle

To connect the manual pulse generator, the R041 or R042 cable is connected to "HANDLE". Up to two
manual pulse generators can be connected. When manufacturing the R041 or R042 cable, use the
connector set CS000 (optional, with two ends). (Refer to Appendix 2.4 R041 Cable, and Appendix 2.5
R042 Cable for cable details.)
To Connect one manual pulse generator
Manual pulse generator
FCUA-HD60
Rear view
NO.1
12V
0V
A
To connect two manual pulse generators
Manual pulse generator
FCUA-HD60
Rear view
NO.2
12V
0V
A
B
When connecting the second manual pulse generator, connect the SEL* signal to the No. 1's 0V.
CAUTION
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power
is ON.
7. Remote I/O Unit Connection
7.11 Connection of FCUA-DX13* Unit and Handle
B
4-M3
R041 cable
NO.1
12V
0V
A
B
SEL*
4-M3
R042 cable
65
FCUA-DX13*
HANDLE
20
10
11
1
Pin No.
HANDLE
FCUA-DX13*