Connection Of Base I/O Unit Power Supply - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

5.5.6 Connection of Base I/O Unit Power Supply

Supply the +24V power to the base I/O unit from the DCIN connector.
Stabilized power
+24V
GND
FG
(Prepare separately.)
(Note) A +24V power supply must be input for both the sink type and source type.
CAUTION
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
Incorrect connections may damage the devices, so connect the cables to the specified
connectors.
5. Base I/O Unit Connection
5.5 Base I/O Unit Input/Output Specifications
DCIN
Base I/O unit
+24V
GND
NC
40